Home station  
Set as homepage Add to favorites    中文版 繁体 English
 
Testing to: Rolling Fire testing | Building Fire testing | Marine material | Aircraft material | Fire Resistance | Jet Fire | Other
   
User name:
Password:
Code:
   
Fire standard
RailwayMarineBusBuilding
Test method More>>
BS 476-6:1989+A1:2009 fire...
BS 476-7:1997 Classificati...
BS 476-20:1987 fire resist...
BS ISO 4589-2:2006-06
NF P 92-501: M classificat...
NF P 92-503: M classificat...
NF P 92-504: Speed of spre...
ASTM E 662: Smoke density ...
ASTM E 648 Flooring test
ASTM E 162: surface flamma...
 
Home   Popular Standard   How can I obtain the CE label and DoP document for the CE certification of EN14889-1 steel fibers? Nanjing Smart EU CE Certification
 

How can I obtain the CE label and DoP document for the CE certification of EN14889-1 steel fibers? Nanjing Smart EU CE Certification

When exporting domestic steel fiber products to the EU market, we often encounter questions such as which company can provide CE certification for steel fibers? How can we obtain the CE label and DoP document?

Nanjing Smart is the domestic authorized institution for the EU NB notified laboratory, providing formal and authoritative EN14889-1 steel fiber CE certification issued by the EU notified laboratory to ensure the smooth sale of products in the EU and other markets. Nanjing Smart not only has the authoritative endorsement of the EU notified laboratory, but also has practical experience in more than ten steel fiber CE certifications, providing customers with one-stop authoritative EN14889 steel fiber CE certification. Consultation phone: +86 25-8658 3475. 

Steel fibers EN 14889-1 CE Certificate standard

EN 14889-1:2006 Fibers for concrete-Part 1: Steel fibers-Definitions, specification and conformity.

Steel fibres include wavy steel fibres, straight steel fibres, end-hooked steel fibres, etc. For more information about the CE certification of concrete fibres, please refer to the official website of Ruidu at http://www.hksmartps.com/ce/steelfibres

EN 14889-2:2006 Fibers for concrete-Part 2: Polymer fibers-Definitions, specification and conformity.

Main testing items for CE certification of EN14889-1 steel fiber
1.Length
2.Diameter
3.Aspect ratio
4.Tensile strength
5.Modulus of elasticity
6.……

EN14889-1 steel fiber CE certification regulations and system:

Steel fiber CE certification is conducted in accordance with the EU CPR construction product regulations, using System 1 or System 3 for testing and certification based on the harmonized standard EN 14889-1. System 1 requires a Notified Body (NB) with an EU notification number to conduct continuous supervision of the factory and perform product testing and evaluation. System 3 requires a Notified Body with an EU notification number to conduct testing on the factory's products.
The certification fees and requirements for the steel fiber CE certification system 3 and system 1 are completely different. Please consult Nanjing Smart Company for details.

Nanjing Smart is an authorized cooperative laboratory for EU announcement numbers NB1301 and NB1020, specializing in CE certification of EU construction products for over ten years. It has extensive experience in CE certification of building materials and CPR regulations. The consultation telephone number +86 25-8658 3475.

EN14889-1 Steel Fiber CE Certification
Nanjing Smart Consulting Tel: +86 25-8658 3475
Website: www.fire-test.com 
Email: info@fire-test.com 
WeChat Official Account:  firetesting or 177 1418 9018


A little knowledge about steel fiber concrete
Fiber-reinforced concrete (FRC) is concrete that has fibrous materials mixed in to increase the concrete’s durability and structural integrity. FRC has small, short, and discreet fibers that are randomly oriented yet uniformly distributed throughout the concrete. The fibers can be circular or flat and often make up one to three percent of the concrete mix’s total volume. Common fibers used in reinforced concrete include steel, glass, synthetic, and natural fibers.

Why fibres are used?
On its own, concrete lacks tensile strength and is prone to cracking. But fiber-reinforced concrete can improve tensile strength and control cracking in concrete structures that are often caused by plastic shrinkage and drying shrinkage. Fibers in concrete can also reduce the permeability of concrete, which limits the amount of water that bleeds out, further reducing shrinkage cracking during curing.

The necessity of Fiber Reinforced Concrete
1- It increases the tensile strength of the concrete.

2- It reduces the air voids and water voids the inherent porosity of gel.

3- It increases the durability of the concrete.

4- Fibers such as graphite and glass have excellent resistance to creep, while the same is not true for most resins. Therefore, the orientation and volume of fibers have a significant influence on the creep performance of rebars/tendons.

5- Reinforced concrete itself is a composite material, where the reinforcement acts as the strengthening fiber and the concrete as the matrix. It is therefore imperative that the behavior under thermal stresses for the two materials be similar so that the differential deformations of concrete and the reinforcement are minimized.

6- It has been recognized that the addition of small, closely spaced, and uniformly dispersed fibers to concrete would act as a crack arrester and would substantially improve its static and dynamic properties.

Types of Fibers 
1- Steel fibers 
2- Glass fibers 
3- Carbon Fibers 
4- Cellulose Fibers 
5- Synthetic Fibers 
6- Natural Fibers 

Advantages Of Fibre Reinforced Concrete

1-High modulus of elasticity for effective long-term reinforcement, even in the hardened concrete. Does not rust nor corrode and requires no minimum cover.

2-Ideal aspect ratio (i.e. the relationship between Fiber diameter and length) which makes them excellent for early-age performance.

3-Easily placed, Cast, Sprayed and less labor-intensive than placing rebar.

4-Greater retained toughness in conventional concrete mixes.

5-Higher flexural strength, depending on the addition rate.

6-Can be made into thin sheets or irregular shapes.

7-FRC possesses enough plasticity to go under large deformation once the peak load has been reached and high flexural rigidity

8-Reduced permeability, bleeding, and formation of microcracks.

9-Minimum weathering effect. 

10-Reduces deflection. 

11-Minimum corrosion.

Nanjing Smart is an authorized cooperative laboratory for EU announcement numbers NB1301 and NB1020, specializing in CE certification of EU construction products for over ten years. It has extensive experience in CE certification of building materials and CPR regulations. For inquiries, please call +86 25-8658 3475.

Nanjing Smart Company Consulting Hotline: +86 25-8658 3475, +86 25 8658 3465
Website: www.hksmartps.com       www.cprce.com 
Email: info@hksmartps.com

……

 Source:防火网  Addtime:11/28/2024  Hits:36

 Previous : AS 4072.1 Fire-resistant isolation components - Fire-resistant testing of penetrations and control joints

 Next: Can the service life of PPR water pipes really reach 50 years? ISO 9080 uses extrapolation to determine the long-term hydrostatic strength of thermoplastic pipes
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved
TEL:(+86)-25-8658 3475