Home station  
Set as homepage Add to favorites    中文版 繁体 English
 
Testing to: Rolling Fire testing | Building Fire testing | Marine material | Aircraft material | Fire Resistance | Jet Fire | Other
   
User name:
Password:
Code:
   
Fire standard
RailwayMarineBusBuilding
Test method More>>
BS 476-6:1989+A1:2009 fire...
BS 476-7:1997 Classificati...
BS 476-20:1987 fire resist...
BS ISO 4589-2:2006-06
NF P 92-501: M classificat...
NF P 92-503: M classificat...
NF P 92-504: Speed of spre...
ASTM E 662: Smoke density ...
ASTM E 648 Flooring test
ASTM E 162: surface flamma...
 
Home   Train   BS 6853:1999 Cable testing
 

BS 6853:1999 Cable testing

Cable testing for BS6853:1999

 

BS6853:1999-Code of practice for fire precautions in the design and construction of passenger carrying trains.

 

BS EN 50266-1:2001 Together with BS EN 50266-2-1, BS EN 50266-2-2, BS EN 50266-2-3, BS EN 50266-2-4, BS EN 50266-2-5,it supersedes BS EN 4066-3 which is withdrawn.

 

As the cable flame spread and burning rate of destruction of the length of the combustion smoke density (light penetration) and the burning of hazardous toxic gas escape on the staff of life play a very important influence. In general, testing cables through these areas to assess.

 

Cable according to end-useInterior cables -BS6853 Table 13Exterior cables-BS6853 Table 14carry out testing and evaluation

 

Cable testing standard for BS6853

 

BS EN 50266-2-4: Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Procedures - Category C (cable diameter ≥12mm)

 

BS EN 50266-2-5: Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Procedures - Category D (cable diameter 12mm)

 

BS EN 50306: Railway applications-Railway rolling stock cables having special fire performance-thin wall

 

BS EN 50305: Railway applications-Railway rolling stock cables having special fire performance-test methods

 

BS EN 50264: Railway applications—Railway rolling stock power and control cables having special fire performance

 

BS 6853 Annex B: Toxicity

 

BS 6853 Annex D: Smoke density

 

BS EN 4066/BS 4066-3: Tests on electric cables under fire conditions. Tests on bunched wires or cables.

 

BS EN 60332-3-24:2009 Tests on electric and optical fibre cable under fire conditions-Part 3-25: Test for vertical flame spread of vertically mounted bunched wires or cables- Category C

 

BS EN 60332-3-24/BS EN 60332-3-25: Tests on electric and optical fibre cable under fire conditions-Part 3-25: Test for vertical flame spread of vertically mounted bunched wires or cables- Category D. It is identical to IEC 60332-3-25:2000, incorporating amendment 1:2008. It supersedes BS EN 50266-2-5:2001 which is withdrawn.

 

、、、、、、

 

BS6853:1999 the main concerns

Flammability

The spread of flame

Toxicity and Density of smoke

 

Tel: (+0086) 25-8658 3475  Tel: (+0086) 400-666-7290


 Source:防火网  Addtime:8/3/2010 Hits:8528

 Previous: EN 45545-2:2020 EU Standard

 Next: NF F 16-101 Cable testing
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved
TEL:(+86)-25-8658 3475