Cable testing for DIN5510-2:2009
DIN 5510-2: Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts, classification, requirement and test methods.
As the cable flame spread and burning rate of destruction of the length of the combustion smoke density (light penetration) and the burning of hazardous toxic gas escape on the staff of life play a very important influence. In general, testing cables through these areas to assess.
Cable testing standard for DIN5510-2
EN 50266-2-4: Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Procedures - Category C (cable diameter ≥12mm)
EN 50266-2-5: Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Procedures - Category D (cable diameter <12mm)
DIN EN 60332-1-2: Tests on electric and optical fibre cables under fire conditions—Part 1-2:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 KW pre-mixed flame and is for general use,
DIN EN 61034-2: smoke density
DIN EN 5659-2: FED(tzul)Toxicity testing, requirement FED(tzul)≤1
Other standard:
DIN 5510-1:1988 Preventive fire protection in railway vehicles; levels of protection, fire preventive measures and certification
DIN 5510-2:2009 Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts- Classification, requirements and test methods.
DIN 5510-4:1988 Preventive fire protection in railway vehicles; Vehicle design; safety requirements
DIN 5510-5:1988 Preventive fire protection in railway vehicles; electrical equipment; safety requirements
DIN 5510-6: Preventive fire protection in railway vehicles; auxiliary measures emergency brake operating function; information systems. fire alarms. fire fighting equipment; safety requirements
Tel: (+0086) 25-8658 3475 Tel: (+0086) 25 8658 3465
|