Home   Train   NF F 16-101 Cable testing
 

NF F 16-101 Cable testing

NFF16-101-Railway rolling stock fire behavior choice of material
NFF16-102-Railway rolling stock fire behavior choice of material –Electrical Equipment

As the cable flame spread and burning rate of destruction of the length of the combustion smoke density (light penetration) and the burning of hazardous toxic gas escape on the staff of life play a very important influence. In general, testing cables through these areas to assess.

NFF16-101/102 only testing for cable insulation, to assess the fire retardant properties of the cable. (Due to the metal conductor and the wire cable with non-flammable)

Main standard the following

I grade oxygen index test: I0-I4 (I0, I1, I2, I3, I4) according to EN 60695-2-11(glow wire test) and EN 4589-2 (oxygen index test) together to assess the I-level oxygen index.

F-class smoke toxicity testing: F0-F5 (F0, F1, F2, F3, F4, F5) according to NF X 10-702 (smoke density test) and the NF X 70-100 (toxicity testing) together to assess the level F smoke toxicity

Wire and cable C1, C2 level test: NF C 32-070 C1, C2, NF C 32-070 C1-level cable test requirements stricter than the NF C 32-070 C2 Multi. C1 grade flame retardant cables used in place stringent requirements, testing is carried out using specialized equipment. Test when a160CMcable hung vertically on the sample rack, the role of radiation under the ignition furnace test, tests 30MIN, 10MIN stop every ventilation 1MIN, test, cable intact chimneys above, the cable C1 level. 

……

NFF16-101 the main concerns

Flammability
The spread of flame
Toxicity and Density of smoke

Tel: +86 25 86583475  +86 25 86583465
Website: http://www.fire-test.com    http://www.firete.com
Mail: info@fire-test.com 

……

 Source:防火网  Addtime:5/18/2023 Hits:9640

 Previous: BS 6853:1999 Cable testing

 Next: DIN 5510-2:2009 Cable testing
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved
TEL:(+86)-25-8658 3475