Fire standard
RailwayMarineBusBuilding
Test method More>>
BS 476-6:1989+A1:2009 fire...
BS 476-7:1997 Classificati...
BS 476-20:1987 fire resist...
BS ISO 4589-2:2006-06
NF P 92-501: M classificat...
NF P 92-503: M classificat...
NF P 92-504: Speed of spre...
ASTM E 662: Smoke density ...
ASTM E 648 Flooring test
ASTM E 162: surface flamma...
 
Home   Popular Standard   Wire and cable EN45545-2 the latest version of the European standard locomotive material fire inspection
 

Wire and cable EN45545-2 the latest version of the European standard locomotive material fire inspection

With the rapid development of railway bus vehicles, high-speed rail has become a synonym for fast and safe travel. With the improvement of the speed of high-speed rail, the requirements for locomotive materials are becoming more and more strict. The EN45545-2, as a global fire assessment requirement, has been updated with the progress of The Times. The latest version of EN45545-2 is the 2020 version, and the wire and cable EN45545-2 is tested according to the requirements of R15 or R16. Nanjing Smart has assisted many cable factories to apply for and complete the EN45545-2 test, and has rich experience in cable fire testing. Contact the hotline: +86 25-86583475.

The latest 2020 EN45545-2 divides materials into 28 categories (R 1 to R 28) depending on the end use of the material. Cables are tested per R15 and R16, where R15 is for internal cables and R16 is for external cables.

EN45545-2:2020 Standard name:
EN 45545-2:2020 Railway applications-Fire protection on railway vehicles Part 2: Requirements for fire behaviour of materials and component

EN 45545-2:2020 R15 / R16 test item
EN 60332-1-2 cable single vertical combustion test
EN 60332-3-24 Multiple vertical combustion test or EN 50305 9.1.1 or EN 50305 9.1.2
EN 61034-2, cable smoke density test
EN 50305 9.2 Cable toxicity test

Among them, a number of bundle test based on the diameter of the cable, the selection of test methods are also different, specific can contact Nanjing Smart.

EN 45545-2:2020 R15 / R16 Test requirements
In EN45545-2 R15 / R16, according to the test results, cables can be divided into three fire risk levels (HL 1 to HL3), among which HL 3 represents the highest fire risk and the best performance of the material.

Single vertical: 50mm mark <540mm mark
Multiple bundles: combustion length 2.5m or 1.5m
 Smoke density: different levels of smoke have different transmittance requirements
Toxicity: Five toxic gases were collected and analyzed to calculate the ITC value.


EN 45545-2:2020 R15/R16 Related reading
EN 45545-2:2020 https://www.fire-test.com/newsinfo/1156098.html
BS6853:1999   https://www.fire-test.com/newsinfo/2330994.html
DIN5510-2  https://www.fire-test.com/newsinfo/2330994.html
NF F16-101/NFF16-102  https://www.fire-test.com/newsinfo/2331076.html
GB8624-2012   https://www.fire-test.com/newsinfo/2331046.html
NFPA130:2017 https://www.fire-test.com/newsinfo/2331009.html
NFPA130:2020 https://www.fire-test.com/newsinfo/1919228.html

Nanjing Smart Contact information:
Tel.: +86 25-8658 3475  +86 25 8658 3465
URL: www.fire-test.com   www.firete.com
Email: info@fire-test.com
Wechat: firetesting or 177 1418 9018
……

 Source:防火网  Addtime:5/31/2024  Hits:155

 Previous : Smart Provide indoor water-based non-expansion steel structure fire retardant coating BS 476-20 & BS 476-22 fire resistance test

 Next: What are the grade requirements for wire and wire and cable standard NF F16-101 test?
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved
TEL:(+86)-25-8658 3475