Home station  
Set as homepage Add to favorites    中文版 繁体 English
 
Testing to: Rolling Fire testing | Building Fire testing | Marine material | Aircraft material | Fire Resistance | Jet Fire | Other
   
User name:
Password:
Code:
   
Fire standard
RailwayMarineBusBuilding
Test method More>>
BS 476-6:1989+A1:2009 fire...
BS 476-7:1997 Classificati...
BS 476-20:1987 fire resist...
BS ISO 4589-2:2006-06
NF P 92-501: M classificat...
NF P 92-503: M classificat...
NF P 92-504: Speed of spre...
ASTM E 662: Smoke density ...
ASTM E 648 Flooring test
ASTM E 162: surface flamma...
 
Home   France   NF F 16-101/NF P 92-503: M classification combustion test
 

NF F 16-101/NF P 92-503: M classification combustion test

NF F 16-101/NF P 92-503: M classification combustion test

 

1. Standard-- NF F 16-101/NF P 92-503

NF P 92-503: Electrical burner test used for flexible materials thickness no more than 5mm

2. Test method—NF F 16-101/NF P 92-503

A specimen in placed in a specimen holder at 30° above a radiator which gives out heat(30kW/m²). A small butane flame is applied directly to the fabric surface.  The following aspects are recorded:  

- duration of the flame

- production of burning droplets

- length/width of the damaged specimen

If specific, unusual, specimen behaviour is observed additional supplementary tests NF P 92-504 & NF P 92-505) may be required.

 

3. M Classification: M0-M4(M0M1M2M3M4)

 

Method

Classes

NF P 92 - 505

-

No ignition of the wool

No ignition of the wool

Ignition of the wool

Ignition of the wool

NF P 92 - 503

No droplets

Not-burning droplets

Burning droplets

Not-burning droplets

Burning droplets

Ignition time =< 5s

M1

M1

M2

M4

M4

Ignition time > 5s; damaged length < 350mm

M2

M2

M3

M4

M4

Ignition time > 5s; damaged length between 450mm and 600mm; damaged width < 90mm

M3

M3

M4

M4

M4

NF P 92 - 504

-

-

M4

M4

M4

 

4.Other Standard of M classification

 

NF P 92-501: Building materials- Reaction to fire tests, radiation test used for rigid material or flexible materials thickness more than 5mm.

NF P 92-503: Electrical burner test used for flexible materials thickness no more than 5mm

NF P 92-504: speed of spread of flame test used for the materials which are not intended to be glued on a rigid substrate.

NF P 92-505: Dripping test with electrical radiator, used for melting materials.

 

5. NF P 92-503/ NF F 16-101requirement

 

NF P 92-503: Electrical burner test used for flexible materials thickness no more than 5mm.


 Source:防火网  Addtime:12/15/2010 Hits:3405