Home station  
Set as homepage Add to favorites    中文版 繁体 English
 
Testing to: Rolling Fire testing | Building Fire testing | Marine material | Aircraft material | Fire Resistance | Jet Fire | Other
   
User name:
Password:
Code:
   
Fire standard
RailwayMarineBusBuilding
Test method More>>
BS 476-6:1989+A1:2009 fire...
BS 476-7:1997 Classificati...
BS 476-20:1987 fire resist...
BS ISO 4589-2:2006-06
NF P 92-501: M classificat...
NF P 92-503: M classificat...
NF P 92-504: Speed of spre...
ASTM E 662: Smoke density ...
ASTM E 648 Flooring test
ASTM E 162: surface flamma...
 
Home   China   GB 8624:2006 Building products fire testing
 

GB 8624:2006 Building products fire testing

GB 8624:2006 Building products fire testing

 

1.Standard -- GB 8624:2006 building products fire testing

GB 8624:2006 Classification for burning behavior of building materials and products

 

2. Standard Brief-- GB 8624:2006 building products fire testing

GB 8624:2006 This standard replaced GB 8624:1997, this amendment by the European Union standards EN 13501-1:2002.

The standard compared with the GB 86241997 major changes, the main changes are as follows:


- The standard of the paving and pipe insulation materials, combustion provides separately for classification, combustion performance levels by the subscript fl and L to distinguish between, respectively;
- Combustion properties of the material divided by the A-level (homogeneous materials), A-level (composite sandwich materials), B1, B2 and B3 into five levels A1, A2, B, C, D, E, F or AF
AFL1、AFL2、BFL、CFL、DFL 、EFL 、FFL or AL1、AL2、BL、CL、DL 、EL 、FL

 

3. GB 8624 the main concern:

Flammability classification:A1、A2、B、C、D、E、F or AFL1、AFL2、BFL、CFL、DFL 、EFL 、FFL or AL1、AL2、BL、CL、DL 、EL 、FL

Toxicity:T0、T1、T2

Smoke density:S1、S2、S3

dripping:D0、D1、D2

 

4. Test method and classification

 

4.1 Classes of reaction to fire performance for construction products excluding floorings

 

Class

Test method (s)

Classification criteria

Additional classification

A1

GB/T 5464 and

△T≤30℃;and

△m≤50%; and

tf = 0 (no sustained flaming)

-

GB/T 14402

PCS≤2.0MJ/kg (1) and

PCS≤2.0MJ/kg (2) (2a) and

PCS≤1.4MJ/m2 (3) and

PCS≤2.0MJ/kg (4) and

-

A2

GB/T 5464 or

and

△T≤50℃; and

△m≤50%; and

tf≤20s

-

GB/T 14402

PCS≤3.0MJ/kg and

PCS≤4.0 MJ/m2 and

PCS≤4.0MJ/m2 (3) and

PCS≤3.0MJ/kg (4) and

-

GB/T 20284

FIGAR≤120W/S and

LFS<edge of specimen and

THR600S≤7.5MJ

Smoke production and flaming droplets

B

GB/T 20284 and

FIGAR≤120W/S and

LFS<edge of specimen and

THR600S≤7.5MJ

Smoke production and flaming droplets

GB/T8626

Exposure=30s

Fs≤150mm with 60s

C

GB/T 20284 and

FIGAR≤120W/S and

LFS<edge of specimen and

THR600S≤7.5MJ

Smoke production and flaming droplets

GB/T8626

Exposure=30s

Fs≤150mm with 60s

D

GB/T 20284 and

FIGAR≤120W/S and

LFS<edge of specimen and

THR600S≤7.5MJ

Smoke production and flaming droplets

GB/T8626

Exposure=30s <, /P>

Fs≤150mm with 60s

E

GB/T8626

Exposure=15s

Fs≤150mm with 20s

Flaming droplets

F

No performance determined

Class A1: According to GB/T 5464 and GB/T 14402; meet to the standards.

Class A2: According to GB/T 5464、GB/T 14402 and GB/T 20284; meet to the standards.

Class B、C、D: According to GB/T 20284、GB/T 20285、GB/T 8626; meet to the standards.

Class E: According to GB/T 8626; meet to the standards.

Class F: According to GB/T 8626; fail to the standards.

 

4.2 Classes of reaction to fire performance for floorings

Class AFL1: According to GB/T 5464及GB/T 14402; meet to the standards.

Class AFL2: According to GB/T 5464、GB/T 14402及GB/T 11785; meet to the standards.

Class BFL、CFL、DFL: According to GB/T 11785、GB/T 8626、GB/T 20285; meet to the standards.

Class EFL: According to GB/T 11785; meet to the standards.

Class FFL: According to GB/T 11785; meet to the standards.

 

4.3 Classes of reaction to fire performance for linear pipe thermal insulation products.

Class AL1: According to GB/T 5464 and GB/T 14402; meet to the standards.

Class AL2: According to GB/T 5464、GB/T 14402 and GB/T 20284; meet to the standards.

Class BL、CL、DL: According to GB/T 20284、GB/T 20285、GB/T 8626; meet to the standards.

Class EL: According to GB/T 8626; meet to the standards.

Class FL: According to GB/T 8626; fail to the standards.

 

5.Application GB 8624Fire testing materials:

Rubber Product、Rubber seal

Ceiling Covering

Walling Covering

Textile、Non-woven fabrics Curtain、Curtain、Adumbral Product

Seat shell、Seat trim

Flooring Covering、PVC Flooring covering

Cable、Cable tie、Cable tube

Foam material、Sponge、Melamine Foam

Paint、Adhesive、Pigment、Varnish

FRP composite materials、SMC sheet

Braided hose、Hose protection

Window、door 、framework

Small parts

Connector、Connected equipment

pipe、corrugate pipe、Heating pipe、Cooling pipe

Other materials

Tel: (+86) 025-8658 3475


 Source:防火网  Addtime:9/2/2010 Hits:9305

 Previous: No related posts

 Next: GB/T 8626-2007-Test method of flammability for building materials
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved