 EN50306: Railway rolling stock cables having special fire performance thin wall 
EN50306-1: Railway applications--Railway rolling stock cables having special fire performance thin wall—part 1 General requirement 
EN50306-2: Railway applications--Railway rolling stock cables having special fire performance thin wall Part 2: Single core cable 
EN50306-3: Railway applications--Railway rolling stock cables having special fire performance thin wall-Part 3: Single core and multicore cables (parts, triples and quads) screened and thin wall sheathed  
EN50306-4: Railway applications--Railway rolling stock cables having special fire performance thin wall—Part 4: Multicore and multipair cables standard wall sheathed    
EN50306 included are: the rated voltage of 300V (ground) conductor 0.5mm2-2.5mm2 EN50306 test focused on the following areas 
  
Flame propagation (flame spread)-bunched cables 
Cable with diameter more than or equal to 12mm 
 
The completed cable shall be tested in accordance with EN 50266-2-4, and shall conform to the recommended performance requirements given in annex B of that standard. 
Cables with diameter greater than 6mm and less than 12mm 
The completed cables shall be tested in accordance with 9.1.1 of EN50305. 
Cable with diameter not greater than 6mm 
The completed cables shall be tested in accordance with 9.1.2 of EN50305 
  
Smoke emission  
 
The completed cable shall be tested in accordance with EN 50268-2 
 |