Home   Popular Standard   CAN/ULC-S102.3 Canadian Building Materials
 

CAN/ULC-S102.3 Canadian Building Materials

Test Method for surface combustion Characteristics of Building Materials is suitable for all types of building materials. Canadian Building Code NBC2010 requires that the combustion characteristics of building materials surfaces should comply with the CAN/ULC-S102 test method. For lamp products, the Canadian surface combustion test standard is CAN/ULC-S102.3, which refers to the test method of CAN/ULC-S102. Due to the particularity of the lamp product structure, the sample requirements will be slightly different from ULC-S102. The specific requirements of CAN/ULC-S102.3 can contact Nanjing Smart, hotline: +86 25-86583475

The danger involved in this trial is the rapid spread of fire across the ceiling, posing a direct threat to life in areas such as open office buildings, and a secondary threat in smaller enclosed spaces due to reduced flashover time. So, even in a small room, delay the development of the fire, minimize the smoke damage to adjacent areas and the risk of fire outbreaks from the cabin, and make it easier to extinguish the fire.

Spiked CAN/ULC-S102.3 Flame Resistance Test for Building Materials-Standard Name:
CAN/ULC-S102.3: diffuser and lens fire test method for Standard method of fire test of light diffusers and lenses lamps

Spiked CAN/ULC-S102.3 Flame Resistance Test for Building Materials-Test Method:
This standard refers to the test equipment of S102 and calibrates and adjusts the test equipment according to the requirements in CAN/ULC-S102. The test was required at least two times, one by simply supporting the specimen on the stove rack and the other by holding the edges with the weight of the lid of the test device along its length so that the edges are completely constrained.

The test shall be terminated immediately at the first test if:
1.The sample has been set on fire,
2.The test sample was dropped onto the floor; or
3.The test sample was neither ignited nor dropped to the floor, and had passed for 10 minutes since the gas burner was ignited.

Spiked CAN/ULC-S102.3 Flame retardant Test for Building Materials-Test Samples:
At least 2 tablets of 3,600mm * 600 mm

Other building materials standards:
EN 13501-1 https://www.fire-test.com/newsinfo/2319002.html
DIN 4102-1 https://www.fire-test.com/newsinfo/838355.html
NF P92-501 https://www.fire-test.com/newsinfo/2337751.html
NF P92-503 https://www.fire-test.com/newsinfo/2337836.html
BS 476-6 https://www.fire-test.com/newsinfo/6541071.html
BS 476-7 https://www.fire-test.com/newsinfo/836481.html

You can follow our public account "firetest" for more information

Nanjing Smart consulting telephone number: +86 25-8658 3475 +86 25-86583465
URL:www.fire-test.com
Email: info@fire-test.com
……

 Source:防火网  Addtime:6/11/2024  Hits:154

 Previous : Bolt nuts are exported to EU CE certification / EN14592 / EN14545 and other certification standards

 Next: High strength bolts, nuts, gaskets EN14399 EU CE certification (EU mandatory CE certification)
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved
TEL:(+86)-25-8658 3475