Home station  
Set as homepage Add to favorites    中文版 繁体 English
 
Testing to: Rolling Fire testing | Building Fire testing | Marine material | Aircraft material | Fire Resistance | Jet Fire | Other
   
User name:
Password:
Code:
   
Fire standard
RailwayMarineBusBuilding
Test method More>>
BS 476-6:1989+A1:2009 fire...
BS 476-7:1997 Classificati...
BS 476-20:1987 fire resist...
BS ISO 4589-2:2006-06
NF P 92-501: M classificat...
NF P 92-503: M classificat...
NF P 92-504: Speed of spre...
ASTM E 662: Smoke density ...
ASTM E 648 Flooring test
ASTM E 162: surface flamma...
 
Home   Popular Standard   BS EN 1154 & BS EN 1155 – CE Marking DOOR CLOSERS
 

BS EN 1154 & BS EN 1155 – CE Marking DOOR CLOSERS

√BS EN 1154: Controlled Door Closing Devices
The standard provides details on product types, classification by use, test cycles, door mass, corrosion resistance, as well as definitions, product performance requirements, test apparatus, test methods and marking of products. In addition, the published standards include annexes illustrating the various points made through diagrams and supplementary text.

◆SCOPE
Products included within the standard are illustrated below and include a wider range than covered by BS6459.

◆CLASSIFICATION
BS EN 1154 classifies door furniture by using an 6 digit coding system. A similar classification applies to all building hardware product standards so that complementary items of hardware can be specified to, for instance, a common level of corrosion resistance, category of use, etc. Each digit refers to a particular feature of the product measured against the standard’s performance requirements.

◆Digit 1 – Category of use
For all internal and external doors for use by the public, and others, with little incentive to take care, i.e. where there is some chance of misuse of the door.

– grade 3: For closing doors from at least 105° open
– grade 4: For closing doors from 180° open

Note 1: Grade 4 classification assumes standard installation according to the manufacturer’s instructions.

Note 2: For applications subject to extremes of abuse, or for particular limitations of opening angle, door closers incorporating a backcheck function or provision of a separate door stop should be considered.

◆Digit 2 – Number of test cycles
Only one test duration is identified for door closers manufactured to this standard:
– grade 8: 500 000 test cycles

◆Digit 3 – Test door mass/size
Seven test door mass grades and related door closer power sizes are identified according to table 1 of this standard. Where a door closer provides a range of power sizes both the minimum and the maximum sizes shall be identified.

◆Digit 4 – Fire behavior
Two grades of fire behavior are identified for door closing devices manufactured to this standard:

– grade 0: Not suitable for use on fire/smoke door assemblies
– grade 1: Suitable for use on fire/smoke door assemblies, subject to satisfactory assessment of the contribution of the door closer to the fire resistance of specified fire/smoke assemblies. Such assessment is outside the scope of this European Standard (see EN 1634-1).

◆Digit 5 – Safety
All door closers are required to satisfy the Essential Requirement of safety in use. Therefore only grade 1 is identified.

◆Digit 6 – Corrosion resistance
Five grades of corrosion resistance are identified according to EN 1670:

– grade 0: No defined corrosion resistance
– grade 1: Mild resistance
– grade 2: Moderate resistance
– grade 3: High resistance
– grade 4: Very high resistance

◆CE marking
Door closers intended for use on fire resisting doors and smoke control doors are covered by a Construction Products Directive mandate issued by the European Commission. Consequently, this standard is regarded as a “harmonised” standard and compliance with it, supported by suitable evidence, allows the application of the CE mark.

√BS EN 1155 – Electrically powered hold-open devices for swing doors
The standard provides details on product types, classification by use, test cycles, door mass, corrosion resistance, as well as definitions, product performance requirements, test apparatus, test methods and marking of products. In addition, the published standard includes annexes illustrating the various points made through diagrams and supplementary text.

◆SCOPE
This European standard specifies requirements for separate hold-open devices and also for hold-open mechanisms incorporated in a door closer. Electrically powered hold-open devices for swing doors manufactured according to this European standard can hold a swing door at a fixed position or can allow the door to swing freely. In each case interruption of the electrical supply will cause the controlled door to close positively.

Electrically powered hold-open devices manufactured in accordance with this European standard are recommended for use wherever there is a requirement for reliable hold-open and release of self-closing fire/smoke door assemblies.

Whilst these devices can incorporate smoke or fire detection elements, the performance of those particular elements is outside the scope of this European standard.

◆CLASSIFICATION
BS EN 1155 classifies door furniture by using an 6 digit coding system. A similar classification applies to all building hardware product standards so that complementary items of hardware can be specified to, for instance, a common level of corrosion resistance, category of use, etc. Each digit refers to a particular feature of the product measured against the standard’s performance requirements.

◆Digit 1 – Category of use
Only one category of use is identified for electrically powered hold-open devices.
– grade 3: for doors for use by the public, and others, with little incentive to take care, i.e. where there is some chance of misuse of the door.
Note: for electrically powered hold-open and free-swing door closers, where the opening angle is limited by the device, provision of a separate door stop should be considered.

◆Digit 2 – Number of test cycles
Two test duration are identified for devices manufactured to this European standard:
– grade 5: 50 000 test cycles. For all electrically powered hold-open devices
– grade 8: 500 000 test cycles. For all electrically powered hold-open and free-swing door closers and devices that contain operating arms.

◆Digit 3 – Test door mass
Five door mass grades and related hold-open power sizes are identified according to Table 1 of this European standard.
Where an electrically powered hold-open device is suitable for a range of door closer power sizes, both the minimum and maximum power sizes shall be shown.

◆Digit 4 – Fire resistance
Only one grade of fire resistance is identified for electrically powered hold-open devices manufactured to this European standard:
– grade 1: Suitable for use on fire/smoke door assemblies subject to satisfactory assessment of the contribution of the electrically powered hold-open device to the fire resistance of specified fire/smoke door assemblies. Such assessment is outside the scope of this European standard (see EN 1634-1).

◆Digit 5 – Safety
Electrically powered hold-open devices are required to satisfy the Essential Requirement of safety in use. Therefore only grade 1 is identified.

◆Digit 6 – Corrosion resistance
Five grades of corrosion resistance are identified in accordance with EN 1670:
– grade 0: no defined corrosion resistance.
– grade 1: mild resistance.
– grade 2: moderate resistance.
– grade 3: high resistance.
– grade 4: very high resistance.

◆CE MARKING
Electrically powered hold open devices intended for use on fire resisting doors and smoke control doors are covered by a Construction Products Directive mandate issued by the European Commission. Consequently, this standard is regarded as a “harmonised” standard and compliance with it, supported by suitable evidence, allows the application of the CE mark.

Tel: +86 25 86583475        +86 25 86583465
Website: www.cprce.com   www.hksmartps.com
Mail: info@hksmartps.com
wechat: firetesting  or  17714189018

...

 Source:防火网  Addtime:9/12/2023  Hits:324

 Previous : What is the difference between LPS 1175 and EN1627-EN1630:2011?

 Next: Building Hardware CE Marking Standard & Legislation
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved
TEL:(+86)-25-8658 3475