Home station  
Set as homepage Add to favorites    中文版 繁体 English
 
Testing to: Rolling Fire testing | Building Fire testing | Marine material | Aircraft material | Fire Resistance | Jet Fire | Other
   
User name:
Password:
Code:
   
Fire standard
RailwayMarineBusBuilding
Test method More>>
BS 476-6:1989+A1:2009 fire...
BS 476-7:1997 Classificati...
BS 476-20:1987 fire resist...
BS ISO 4589-2:2006-06
NF P 92-501: M classificat...
NF P 92-503: M classificat...
NF P 92-504: Speed of spre...
ASTM E 662: Smoke density ...
ASTM E 648 Flooring test
ASTM E 162: surface flamma...
 
Home   Regulations   GB/T29416-2012 "Test method for fire performance of exterior wall insulation system" has been released
 

GB/T29416-2012 "Test method for fire performance of exterior wall insulation system" has been released

The National Standardization Administration recently issued Announcement No.42 of 2012, approving the release of the recommended national standard GB/T29416-2012 "Test Methods for Fire Performance of Exterior Insulation Systems for Building Facades." This standard is being released for the first time and will be implemented from October 1, 2013.

The national standard GB/T29416-2012 "Test Methods for Fire Resistance Performance of Exterior Insulation Systems on Building Facades" is one of the key standard projects included in the "Twelfth Five-Year Plan for Fire Protection Standardization." The main technical content of this standard is based on the British standard BS8414-1:2002 "Fire Resistance Performance of Exterior Insulation Systems on Buildings-Part 1: Test Methods for Non-load-bearing Externally Insulated Systems Suitable for Building Surfaces" and LPS15812nd Edition: 2010 "Requirements and Test Methods for LPCB Certification of Non-load-bearing Exterior Insulation Systems Applied to Masonry Walls of Buildings," while fully considering the application status of exterior insulation systems on building facades in China. Through extensive experimental verification, it details the test equipment, specimens, condition adjustment, test procedures, post-test inspections, test result evaluation, and test report content for the fire resistance performance tests of exterior insulation systems on building facades.

The test methods specified in this standard are scientific and reasonable, meeting the production, application, and technical development needs of Chinas building exterior wall insulation systems, with an overall level reaching international advanced standards. The release and implementation of this standard will provide a technical basis for fire performance testing of Chinas building exterior wall insulation systems.

Nanjing Smart provides comprehensive fire resistance test services: https://www.fire-test.com/newsinfo/4260230.html

Building materials: GB 8624, EN 13501-1, BS 476-4, BS 476-6, BS 476-7, DIN 4102-1, NF P92-501, NF P92-503, NF P92-507, ASTM E162, ASTM E84, ASTM E648, EN ISO 5660-1, ISO 5658-2, ISO 1716, EN 4589, AS 1530.1, AS 1530.3, ASTM E662, ISO 5659-2

Fire-resistant components: ISO 834-1, GB 9978, GB 14102, GB 14907, GB/T 7633, EN 1363, EN 1364, EN 1366, EN 45545-3, BS 476-20, BS 476-21, BS 476-22, BS 476-23, ASTM E119, ASTM E814, AS 1530.4

Track vehicles: EN 45545-2, EN 45545-3, TB/T 3237, NFPA 130, TB 3138, NF F16-101, BS 6853, DIN 5510-2, UIC 564-2

Ship equipment: IMO FTPC Part 1 / Part 2 / Part 3 / Part 4 / Part 5 / Part 6 / Part 7 / Part 8 / Part 9

Nanjing Smart Contact Information:
Tel: +86-25-8658 3475
Web: www.fire-test.com
Email: info@fire-test.com
WeChat: 177 1418 9018  or  firetesting



 Source:防火网  Addtime:1/3/2025 Hits:23

 Previous: CNAS & ILAC Lab for ASTM E814 Fire Tests of Penetration Firestop systems

 Next: Marble tile Australia NATA AS4964 asbestos free testing certification/Non asbestos testing
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved
TEL:(+86)-25-8658 3475