Home station  
Set as homepage Add to favorites    中文版 繁体 English
 
Testing to: Rolling Fire testing | Building Fire testing | Marine material | Aircraft material | Fire Resistance | Jet Fire | Other
   
User name:
Password:
Code:
   
Fire standard
RailwayMarineBusBuilding
Test method More>>
BS 476-6:1989+A1:2009 fire...
BS 476-7:1997 Classificati...
BS 476-20:1987 fire resist...
BS ISO 4589-2:2006-06
NF P 92-501: M classificat...
NF P 92-503: M classificat...
NF P 92-504: Speed of spre...
ASTM E 662: Smoke density ...
ASTM E 648 Flooring test
ASTM E 162: surface flamma...
 
Home   Regulations   Testing according to EN 15651 of sealants for non-structural use in joints in buildings and pedestrian walkways (CE Certificate)
 

Testing according to EN 15651 of sealants for non-structural use in joints in buildings and pedestrian walkways (CE Certificate)

The standard EN 15651 is a series of standads that specifies definitions and requirements for sealants for non-structural use in joints in buildings and pedestrian walkways. The separate parts of the standard (part 1- 4) contain the different applications of sealants with the corresponding test specifications. Part 5 includes the description for evaluation of conformity and marking of individual products. 

This standards series specifies definitions and requirements for cold applied non-structural elastic sealants used for movement joints in floors in building construction for interior and exterior use, e.g. for pedestrian walkways and public areas. The contents of the standard parts of EN 15651-1 to -4 are specified below.

Part 5 comprises the determinations for evaluation of conformity, thus the initial type testing of the product as well as the corresponding necessary factory production control. The products have to be put to the corresponding initial type testing. On basis of the initial type testing, the classification will be determined if the result is positive and a classification report will be issued. If the standard-compliant factory production control is present, the products can be marked according to the specifications of EN 15651-5. 

Tests sealants according to the following standards:
EN 15651-1 Sealants for facade elements:
This part is for non-structural facade sealants intended for sealing exterior wall joints, window and door perimeter joints in building construction, including the interior face. The requirements, definitions and the tests to be carried out are specified in this part of the standard. 
 
EN 15651-2 Sealants for glazing:
Part 2 of this standard specifies the areas for non-structural elastic sealants used for sealing glazing in building construction applications. These sealants are mostly used in the areas glass to glass; glass to frame; glass to porous substrates.

The definitions, requirements and tests for this glazing joints from 7° horizontal are specified in this part.
 
EN 15651-3 Sealants for sanitary joints:
Sealants used for sealing of joints applied in sanitary areas in the interior of buildings exposed to non-pressurised water are covered with part 3. This part of the standards applies for joints in bathrooms; toilets; showers; domestic kitchens.
 
EN 15651-4 Sealants for pedestrian walkways:
Sealants can be used for movement joints in floors in building construction for interior and exterior use. Areas of application are: floor joints designed for pedestrian walkways, public areas, movement joints between concrete slabs, areas with pedestrian load, areas used with trolleys, walkable floors, balconies, terraces, warehouses. Sealants used in these areas of application are specified in part 4 of EN 15651.

南京睿督公司免费咨询电话:025-8658 3475   400-603-6575
网址:www.cprce.com    www.fire-test.cn
邮箱:info@fire-test.com 

... 


 Source:防火网  Addtime:6/24/2022 Hits:687

 Previous: Emission of Smoke, Halogens and Toxicity Testing_IEC60754/IEC61034