European EN45545 / EN45545-2-2013 standard for fire and toxicity test
1. The standard - Rail transit vehicle material fire test standard EN45545 /EN45545-2 railway applications - railway vehicle fire protection - part 2: materials and components of the fire protection requirements. The European railway on March 8, 2013 formally announced EN45545-2 updated version of the standard. there are some difference between EN45545-2-2009 and EN45545-2-2013 standard .
2. EN45545 / EN45545-2 standard brief EN45545-2 the latest standard of 2013 edition, the main focus on the combustion performance of materials, thermal properties, such as emission, smoke density and toxicity. EN45545-2 standard according to the material end use, divided into R1 - R26, a total of 26 different categories. Depending on the type of vehicle and the operating environment, EN45545-2-2013 standard could be divided into HL1 fire danger rating, HL2, HL3, a total of three fire risk level. Eu EN45545-2 standard will plan to replace BS6853, NFF16-101,, DIN5510 NFF16-102-2, UNI CEI 11170-3, prE10.02.977.3, UIC564-2 eu railway vehicles materials such as fire test standards.
3. EN45545 / EN45545-2 standard includes the following rail vehicles EN45545-2 standard specifies the following vehicle (subway train high-speed maglev train locomotive train, light rail trams trolleybus coach) fire burning test performance, smoke, toxicity, properties, such as combustion heat value.
4 EN45545 / EN45545-2 main test standard EN ISO 5658-2: building products vertical structure fire expansion EN ISO 5660-1: product test method of the heat release rate EN ISO 5659-2: smoke density products EN 45545 Annex C: toxicity test EN ISO 9239-1: building products vertical structure fire expansion ISO 9705: full scale test method EN ISO 4589: the oxygen index test EN 50266: cable vertical flame combustion EN 50266-2-4: wire and cable root into a bunch of vertical burning test (cable diameter 12 mm or above) EN 50305.9.1.1: railway with thin wall cable fire prevention performance test (6 mm cable diameter < 12 mm) EN 50305.9.1.2: railway with thin wall cable fire prevention performance test (6 mm diameter or less) EN 61034-2: wire and cable smoke concentration test EN 60332-1-2: wire and cable single vertical flame EN 50268-2: wire and cable of smoke density test NF X 70-100: toxicity test
5. EN45545 / EN45545-2 focuses on the following aspects: The oxygen index test Heat release a quantity to test Toxicity test Smoke density Critical heat radiation test
More EN45545-2 the subway train test, please consult Nanjing Smart Company Hotline: 0086 25 8658 3475 Website: www.firete.com Email: info@firete.com ...
|