IMO FTPC Part 2: Smoke and toxicity test
IMO FTPC Part 2: Smoke and toxicity test (ISO 5659-2)
Field of application:
Surface materials for bulkheads and ceilings and similar exposed surfaces, floor coverings
Test time is 10 minutes, recording all smoke density and gas content. Samples exposed to 25 or (50) KW/m2 radiation heat conditions, for testing. By CO2, CO, HF, HCI, HCN, NO2, SO2, HBr gas to analyze the toxicity of the eight
Smoke density classification standard: A test gas than the maximum optical density (Ds) average (Dm) 1. For the bulkhead, lining or ceiling surface, in any experimental conditions, Dm ≤ 200 2. For deck covering material, in any experimental conditions, Dm ≤ 400 3. For the floor surface of the material, in any experimental conditions, Dm ≤ 500 4. For plastic pipes and cables, in any experimental conditions, Dm ≤ 400
Toxicity grading criteria:
CO 1450ppm
HF 600ppm
HCI 600ppm
HCN 140ppm
NO2 350ppm
SO2、 120ppm
HBr 600ppm
IMO MSC 61(67) FTPC – Test list
IMO FTPC Part 1: Non-combustibility test
IMO FTPC Part 2: Smoke and toxicity test
IMO FTPC Part 4: Test for fire door control systems
IMO FTPC Part 5: Test for surface flammability
IMO FTPC Part 6: Test for primary deck coverings
IMO FTPC Part 7: Test for vertically supported textiles and films
IMO FTPC Part 8: Test for upholstered furniture.
IMO FTPC Part 9: Test for bedding components
ISO 9705 and ISO 5660: Test for fire-restricting materials for high-speed craft