1. NF P92-501 Fire test to Building materials M classification - Standard
NF P92-501: Building materials-Reaction to fire tests, radiation test used for rigid material or flexible materials thickness more than 5mm.
2. NF P92-501 Fire test to Building materials M classification - Test Method
Specimens of the product are mounted in an enclosed chamber at an angle of 45° to the horizontal and exposed to thermal radiation (30kW/m2) on their lowest surface, the test duration 20 minutes.
The materials is classified M1 to M4 according to the q index (NF P92-507)
M1 - Non flammable q < 2.5
M2 - Low flammability q < 15
M3 - Moderately flammable q < 50
M4–flammable q ≥50
If specific, unusual, specimen behaviour is observed additional supplementary tests (NF P 92-504 or NF P 92-505) may be required.
3. NF P92-501 Fire test to Building materials M classification - Similar Standard
NF P92-501: Building materials- Reaction to fire tests, radiation test used for rigid material or flexible materials thickness more than 5mm.
NF P92-503: Electrical burner test used for flexible materials thickness no more than 5mm
NF P92-504: speed of spread of flame test used for the materials which are not intended to be glued on a rigid substrate
NF P92-505: Dripping test with electrical radiator, used for melting materials
NF P92-506: Fire safety, Building materials, Reaction for fire tests, Radiant panel test for flooring
NF P92-507: Fire safety, Building materials, Construction and furnishing materials –Classification according to reaction to fire.
Nanjing SMART
Tel : (+86) 25 8658 3475 (+86) 400 6575
web : www.fire-test.com www.fire-test.cn
Email : info@fire-test.com
WeChat Official-"firetest" or "睿督防火测试"
…
|