ASTM E84 Test Method for surface burning of Building Material /ASTM E84 Class A
|
ASTM E84 Fire Test to Building Material – Standard
ASTM E84 Standard test method for surface burning characteristics of building materials
ASTM E84 Fire Test to Building Material – Standard Brief
Flame spread is the development of the flame in the surface, it is related to a fire near combustible Ershi believed the spread of fire. Flame propagation properties of the tunnel method and often radiation plate test.
ASTM E84 Fire Test to Building Material –Test Method
Tunnel test is to test the surface burning characteristics of materials, asbestos and untreated red oak plywood compared. 0 levels of asbestos plywood, 100 level for the untreated red oak flooring. In this test, the smoke produced during combustion also be measured, and divided into within the same class. This level within 10 minutes in the beginning was determined. However, the difference is coated with fire, building specifications to extend the test time from 10 minutes to 30 minutes, the burner flame propagation can not exceed 10 1 / 2 feet, and requires no further signs of burning
Determination of the material with the tunnel of FSI between the value of between 0 to 200, FSI smaller the value of material, the smaller the risk of fire. High-rise building and the corridor should be used FSI( Flame spread Test) <25 materials, 25 100 of the material does not meet flame retardant requirements.
ASTM E84 Fire Test to Building Material –Products Classification
ASTM E84 Class A for the 0-25,smoke index of less than 450
ASTM E84 Class B for the 26-75, smoke index of less than 450
ASTM E84 Class C for the 76-200, smoke index of less than 450
ASTM E84 Fire Test to Building Material – Relative Standard
- BS 476: Fire tests on building materials and structures
- BS 476-7:Fire Tests on Building Materials and Structures Part 7: Method of Test to Determine the Classification of the Surface Spread of Flame of Products
- EN 13501-1: Fire classification of construction products and building elements- Part1: Classification using data from reaction to fire tests
- NF P92-501: Safety against fire - Building materials - Reaction to fire tests - Radiation test used for rigid materials. or for materials on rigid substrates (flooring and finishes) of all thicknesses. and for flexible materials thicker that 5 mm
- NF P92-503: Safety against fire - Building materials – Reaction to fire tests. Electrical burner test used for flexible materials
- GB 8624: Classification for burning behavior of building materials and products
- GB 20286: Requirements and mark on burning behavior of fire retarding products and subassemblies in public place
Nanjing SMART
Tel : (+86) 25 8658 3475 (+86) 400 6575
web : www.fire-test.com www.fire-test.cn
Email : info@fire-test.com
WeChat Official-"firetest" or "睿督防火测试"
…
|
Source:防火网 Addtime:12/31/2021 Hits:990
Previous :
NF P92-501: M classification(French Standard)
Next:
Emission of Smoke, Halogens and Toxicity Testing_IEC60754/IEC61034 |
|
|