防火网
本站  
設為首頁 加入收藏 網站地圖  中文版 繁体 English
 
測試服務: 機車材料防火測試 | 建築產品防火測試 | 船舶防火測試 | 飛機防火測試 | 耐火測試 | 噴射火測試 | 其他測試
   
用戶名:
密碼:
驗證碼:
   
 
主要阻燃防火認證標準
火車船舶汽車建材
 
相關測試方法 更多>>
EN ISO 9239-1:2010地
EN ISO 1182:2010
NF P 92-501
NF P 92-507
法标F级测试
法标I级测试
法国M级测试
EN ISO 1182
EN ISO 9239-1
EN 13501-1
 
首頁   美国   ASTM F1695下烤式烘烤炉性能的标准试验方法
 

ASTM F1695下烤式烘烤炉性能的标准试验方法

ASTM F1695 Standard Test Method for Performance of Underfired Broilers
ASTM F1695 下烤式烘烤炉性能的标准试验方法

The energy input rate test is used to confirm that the underfired broiler is operating properly prior to further testing.
Temperature distribution of the broiling area may be used by food service operators to select an underfired broiler with the desired temperature gradients.
Preheat energy and time can be useful to food service operators to manage energy demands and to know how quickly the underfired broiler can be ready for operation.
Cooking energy efficiency is a precise indicator of underfired broiler energy performance under various loading conditions. This information enables the food service operator to consider energy performance when selecting an underfired broiler.
Production capacity allows the food service operator to select an underfired broiler that meets their food output requirements.

1. Scope
1.1 This test method covers the evaluation of the energy consumption and cooking performance of underfired broilers. The food service operator can use this evaluation to select an underfired broiler and understand its energy performance.
1.2 This test method is applicable to gas and electric underfired broilers.
1.3 The underfired broiler can be evaluated with respect to the following (where applicable):
1.3.1 Energy input rate (see 10.2),
1.3.2 Temperature distribution across the broiling area (see 10.3),
1.3.3 Preheat energy and time (see 10.4),
1.3.4 Pilot energy rate, if applicable (see 10.5),
1.3.5 Cooking energy rate (see 10.6), and
1.3.6 Cooking energy efficiency and production capacity (see 10.7).
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
ASTM A36/A36M Specification for Carbon Structural Steel
ASTM D3588 Practice for Calculating Heat Value, Compressibility Factor, and Relative Density of Gaseous Fuels
ANSI Standard
ANSIZ83.11 American National Standard for Gas Food Service Equipment
AOAC Documents
AOACOfficialAction96 Fat (Crude) or Ether Extract in Meat
ASHRAE Document
ASHRAEGuideline2-198 (RA90) Engineering Analysis of Experimental Data
Other Document
DevelopmentandValida
Index Terms
cook time; energy efficiency; performance; test method; underfired broiler; Cooking energy efficiency (CEE); Cooking/food service equipment; Cooking/food service equipment performance; Energy efficiency; Underfired broilers;

更多防火阻燃测试认证,请咨询南京睿督公司
电话:400-603-6575   025-8658 3475
网址:www.fire-test.com
邮箱:info@fire-test.com

...


 來源:防火網 發布時間:12/2/2013 點擊次數:1101

 上一條: ASTM F1689测定薄膜开关绝缘电阻的标准试验方法

 下一條: ASTM F1720用加热人体模特测量睡袋保温性标准试验方法
 
 
網站首頁 | 測試服務 | 各國標準 | 新聞資訊 | 防火材料 | 會展信息 | 認證服務 | 在線咨詢 | 聯系我們
Copyright © 2009-2023 Firete.com All Right Reserved 蘇公網安備 32010502010088號
服務熱線:+86 25-86583475   備案號:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火網博客