首頁   美国   ASTM F1134船用电动机及发电机绝缘电阻监测仪的规格
 

ASTM F1134船用电动机及发电机绝缘电阻监测仪的规格

ASTM F1134 Standard Specification for Insulation Resistance Monitor for Shipboard Electrical Motors and Generators
ASTM F1134 船用电动机及发电机绝缘电阻监测仪的规格

This specification covers monitoring devices (monitors) for the automatic detection and signaling of low insulation resistance values in idle electrical motors or generators, or both. Monitors are intended for permanent installation in both existing or new panels and controller enclosures designed for marine application. These insulation resistance monitors shall be classified in four types: Type I are alternating current generator monitors, Type II are alternating current generator monitors, Type III are direct current motor monitors, and Type IV are direct current generator monitors. The enclosure materials used in the construction of the monitors are to be flame-retardant and the current carrying terminals shall be made of corrosion resistant material. The monitors shall isolate their measuring circuit from the line voltage, while the motor is operating, by the use of an integral isolating relay. In the design of these monitors, environmental factors shall be considered: operating temperature range, sealing, inclination, humidity, and vibration. Also, the monitor relays, voltage characteristics and operating accuracy shall be considered in the design of these monitors. Each monitor shall be subjected to the following: visual and mechanical examination and operational test.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

1. Scope
1.1 This specification covers monitoring devices (monitors) for the automatic detection and signaling of low insulation resistance values in idle electrical motors or generators, or both.
1.2 Monitors are intended for permanent installation in both existing or new panels and controller enclosures designed for marine application.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
The following safety hazards caveat pertains only to the test method described in this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
UL Standard
UL94 Test for Flammability of Plastic Materials for Parts in Devices and Appliances
IEEE Standards
IEEE100 Standard Dictionary of Electrical and Electronics Terms
Government Standard
Title46 Code of Federal Regulations Shipping
Index Terms
electrical generator; electrical motors; insulation; low insulation resistance values; marine controller enclosures; resistance monitor; shipboard generator; shipboard motors;

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...


 來源:防火網 發布時間:11/29/2013 點擊次數:1108

 上一條: ASTM F1121船舶灭火用国际海岸通讯线

 下一條: ASTM B786次级绝缘用19股单绞捻1350型铝导线
 
 
網站首頁 | 測試服務 | 各國標準 | 新聞資訊 | 防火材料 | 會展信息 | 認證服務 | 在線咨詢 | 聯系我們
Copyright © 2009-2023 Firete.com All Right Reserved 蘇公網安備 32010502010088號
服務熱線:+86 25-86583475   備案號:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火網博客