首頁   美国   ASTM E989撞击缓冲等级(IIC)测定的标准分类
 

ASTM E989撞击缓冲等级(IIC)测定的标准分类

ASTM E989 Standard Classification for Determination of Impact Insulation Class (IIC)
ASTM E989 撞击缓冲等级(IIC)测定的标准分类

The rating increases as the impact sound attenuation of the floor ceiling structure increases. The rating can be used by architects, builders, and specification and code authorities for acoustical design purposes in building constructions.
4.2 The rating strictly only applies to excitation by the standard tapping machine defined in Test Methods E 492 and E 1007. It does not deal with low frequency sounds below 100 Hz that are typically generated below lightweight joist floors when they are walked on. Nor does it deal with the squeaking, crunching or rattling sounds that can occur in joist construction when elements in the construction are loose and occupants walk on the floor.
4.3 This classification shall only be used with one-third octave band data.

1. Scope
1.1 This classification provides a method for determining a rating that can be used to compare the levels of impact noise generated by a standard tapping machine and transmitted through different floor-ceiling assemblies.
1.2 The name given to the rating is assigned by the test method that invokes this classification.
1.3 This classification is applicable only to one third octave band impact noise data obtained using the standard tapping machine described in Test Methods E 492 and E 1007.
1.4 Test methods that invoke this classification include:
1.4.1 Test Method E 492 - the single-number rating is called impact insulation class (IIC).
1.4.2 Test Method E 1007 - the single-number rating is called field impact insulation class (FIIC).
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
ASTM C634 Terminology Relating to Building and Environmental Acoustics
ASTM E492 Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine
ASTM E1007 Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
Index Terms
floors; IIC; impact noise; impact rating; tapping machine;

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...
 


 來源:防火網 發布時間:11/28/2013 點擊次數:1420

 上一條: ASTM E970暴露于辐射热能源搁楼地板绝缘临界辐射通量标准试验方法

 下一條: ASTM E1019钢,铁,镍和钴合金中碳,硫,氮和氧含量测定的标准试验方法
 
 
網站首頁 | 測試服務 | 各國標準 | 新聞資訊 | 防火材料 | 會展信息 | 認證服務 | 在線咨詢 | 聯系我們
Copyright © 2009-2023 Firete.com All Right Reserved 蘇公網安備 32010502010088號
服務熱線:+86 25-86583475   備案號:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火網博客