防火网
本站  
設為首頁 加入收藏 網站地圖  中文版 繁体 English
 
測試服務: 機車材料防火測試 | 建築產品防火測試 | 船舶防火測試 | 飛機防火測試 | 耐火測試 | 噴射火測試 | 其他測試
   
用戶名:
密碼:
驗證碼:
   
 
主要阻燃防火認證標準
火車船舶汽車建材
 
相關測試方法 更多>>
EN ISO 9239-1:2010地
EN ISO 1182:2010
NF P 92-501
NF P 92-507
法标F级测试
法标I级测试
法国M级测试
EN ISO 1182
EN ISO 9239-1
EN 13501-1
 
首頁   美国   ASTM E594气相色谱法或超临界液相色谱法中使用检验火焰电离探测器标准操作规范
 

ASTM E594气相色谱法或超临界液相色谱法中使用检验火焰电离探测器标准操作规范

ASTM E594 Standard Practice for Testing Flame Ionization Detectors Used in Gas or Supercritical Fluid Chromatography
ASTM E594气相色谱法或超临界液相色谱法中使用检验火焰电离探测器标准操作规范

Although it is possible to observe and measure each of the several characteristics of a detector under different and unique conditions, it is the intent of this recommended practice that a complete set of detector specifications should be obtained at the same operating conditions, including geometry, flow rates, and temperatures. It should be noted that to specify a detector’capability completely, its performance should be measured at several sets of conditions within the useful range of the detector. The terms and tests described in this recommended practice are sufficiently general so that they may be used at whatever conditions may be chosen for other reasons.
The FID is generally only used with non-ionizable supercritical fluids as the mobile phase. Therefore, this standard does not include the use of modifiers in the supercritical fluid.
Linearity and speed of response of the recording system or other data acquisition device used should be such that it does not distort or otherwise interfere with the performance of the detector. Effective recorder response, Refs. (5,6) in particular, should be sufficiently fast so that it can be neglected in sensitivity of measurements. If additional amplifiers are used between the detector and the final readout device, their characteristics should also first be established.

1. Scope
1.1 This practice covers the testing of the performance of a flame ionization detector (FID) used as the detection component of a gas or supercritical fluid (SF) chromatographic system.
1.2 This recommended practice is directly applicable to an FID that employs a hydrogen-air or hydrogen-oxygen flame burner and a dc biased electrode system.
1.3 This recommended practice covers the performance of the detector itself, independently of the chromatographic column, the column-to-detector interface (if any), and other system components, in terms that the analyst can use to predict overall system performance when the detector is made part of a complete chromatographic system.
1.4 For general gas chromatographic procedures, Practice E 260 should be followed except where specific changes are recommended herein for the use of an FID. For definitions of gas chromatography and its various terms see Recommended Practice E 355.
1.5 For general information concerning the principles, construction, and operation of an FID, see Refs (1, 2, 3, 4).
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific safety information, see Section .

2. Referenced Documents (purchase separately)
ASTM Standards
ASTM E260 Practice for Packed Column Gas Chromatography
ASTM E355 Practice for Gas Chromatography Terms and Relationships
CGA Standards
HB-3 Handbook of Compressed Gases
Index Terms
flame ionization detector (FID); flame photometric detectors (FPD); gas chromatography (GC); packed columns; supercritical fluid chromatography (SFC);

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...


 來源:防火網 發布時間:11/20/2013 點擊次數:1367

 上一條: ASTM E69经烟管装置处理的木材的燃烧特性的标准试验方法

 下一條: ASTM E603房间防火实验标准指南
 
 
網站首頁 | 測試服務 | 各國標準 | 新聞資訊 | 防火材料 | 會展信息 | 認證服務 | 在線咨詢 | 聯系我們
Copyright © 2009-2023 Firete.com All Right Reserved 蘇公網安備 32010502010088號
服務熱線:+86 25-86583475   備案號:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火網博客