首頁   美国   ASTM E2359外部绝缘和精整系统包壁组件中的现场拉伸测试的标准试验方法
 

ASTM E2359外部绝缘和精整系统包壁组件中的现场拉伸测试的标准试验方法

ASTM E2359  Standard Test Method for Field Pull Testing of an In-Place Exterior Insulation and Finish System Clad Wall Assembly
ASTM E2359 外部绝缘和精整系统包壁组件中的现场拉伸测试的标准试验方法

The purpose of this test method is to assess the installation adequacy and the overall effects of service-related deterioration (moisture, etc.) on the EIFS wall assembly as opposed to small localized areas of degradation. Resistance to pull testing as determined by this test is used as one of the factors in evaluating the EIFS assembly on a specific project. The values obtained by this test method are not purported to be representative of the actual wind load capacity or other structural properties of a specific EIFS clad wall installation, but may be helpful in assessing such load capacities.
Since this test is used for field evaluation of existing facilities, load results obtained from this test must be interpreted based on sound engineering practice, applicable building regulations, and codes having jurisdiction. It is the discretion of the test specifier to directly utilize the results derived by this test method, or else to utilize the test results with an appropriate factor of safety to obtain acceptable working loads for each project.
This method is intended for use on test specimens occurring or installed on existing buildings. The loss of outward wind load resistance of an EIFS wall assembly after exposure to moisture and other weather conditions may compromise the ability of the cladding or other wall components to perform adequately in place. This test method does not provide any means by which the test results may be generalized to the larger wall area. Such efforts should be based on experience and engineering judgement.
The manner in which the test load is applied may affect the load capacity obtained from using this standard. A discussion of various load application techniques and their effects is given in Appendix X1.

1. Scope
1.1 This test method covers a procedure to determine the resistance of a section of the exterior insulation and finish system (EIFS) to outward loads imposed on an existing exterior wall assembly that has been in place on the building for an unspecified period of time. It is destructive in nature within the localized areas tested and requires appropriate repair of the EIFS cladding and sheathing once the test procedure has been completed. This test procedure utilizes mechanical methods to obtain information, which may be helpful in evaluating the natural application of negative wind loads on the EIFS assembly. Some variability of results should be anticipated within the wall assembly tested due to differences in installation procedures, exposure, or abuse subsequent to application.
1.2 This test method is suitable for use on cladding assemblies that have been in place a short time (new construction), as well as for longer periods in order to evaluate detrimental effects on the EIFS lamina, insulation attachment, substrate integrity, and attachments after exposure to weather and other environmental conditions. It is not intended to evaluate the performance of structural framing. Test results on any particular building may be highly variable depending on specimen location and condition, and are subject to interpretation by the test specifier.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
This standard may involve hazardous materials, operations, or equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.
Note 1
Due to variations in exposure and construction assemblies, field specimens selected for testing utilizing this test method may experience sudden failure and release of the imposed loads. See Note 7 for further information.

2. Referenced Documents (purchase separately)
ASTM Standards
ASTM D3665 Practice for Random Sampling of Construction Materials
ASTM E631 Terminology of Building Constructions
ASTM E2110 Terminology for Exterior Insulation and Finish Systems (EIFS)
ASTM E2128 Guide for Evaluating Water Leakage of Building Walls
American Society of Civil Engineers (ASCE)
SEI/ASCE7-05, Minimum Design Loads for Buildings and Other Structures
Index Terms
design wind pressure; design wind loads; DWP; EIFS; Exterior insulation and finish system; face delamination; moisture deterioration; negative pressure; pull test; pull test frame; stud spacing; substrate integrity;

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...

 


 來源:防火網 發布時間:11/18/2013 點擊次數:1287

 上一條: ASTM E2354密封绝缘玻璃设备内吸收性电致变色涂层的耐用性评估用标准指南

 下一條: ASTM E2393安装的防火接头系统和周围防火壁的现场检验的标准规范
 
 
網站首頁 | 測試服務 | 各國標準 | 新聞資訊 | 防火材料 | 會展信息 | 認證服務 | 在線咨詢 | 聯系我們
Copyright © 2009-2023 Firete.com All Right Reserved 蘇公網安備 32010502010088號
服務熱線:+86 25-86583475   備案號:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火網博客