Denmark, Finland, Iceland, Norway and Sweden standard NT001-NT007

The Nordic countries Denmark, Finland, Iceland, Norway and Sweden cooperate within the framework of the Nordic Council in order to include harmonisation of national law while defining an overall classification of material.

Table 1: Nordic council classification

Component

Fire test method

Description

Classification

Material

NT 001

Non-combustibility test

Non-combustible/ combustible

Wall and ceiling lining

NT 003

Fire protection ability of coverings

K0 / K1 / K2

Interior surface finishes

NT 002

Ignitability test

ln 1 / ln 2 / ln 3

Exterior surface finishes

NT 004

Heat release and smoke generation test

Ut 1 / Ut 2

Roofing

NT 006

Roof fire spread

Ta 1 / Ta 2

Floor coverings

NT 007

Flooring fire spread and smoke generation

G



The actual classification used for Finland regulations for the fire behaviour of materials/component is described in the standard National Building Code of Finland, Part E1, Fire Safety of Buildings, 1997. 3 fire classes of building are considered (see tables below):

Table 2: building class tests for all materials excepted floorings

Characteristic

Test

Assessment

Non combustibility

ISO 1182: Fire test for building materials: Reaction to fire, Non-combustibility test

 

Ignitability

SFS 4190:E (NT FIRE 002) Fire tests. Building products: Ignitability
ISO 5657 (NT FIRE 033) Fire tests-Reaction to fire.Ignitability of building products.

Class 1:non-igniting surface
Class 2: slowly igniting surface

Fire spread characteristics

SFS 4192:E (NT FIRE 004) Fire tests. Building products: Heat release and smoke production

Class I: non-fire spreading surface
Class II: slowly fire spreading surface

Table 3: Fire class and use of the building

 

Fire class of the building

 

High fire level requirement

Medium fire level requirement

Low fire level requirement

Dwellings:
Walls and ceilings

2 / -
Slowly igniting surface, No demands for fire spread

1 / I
Non igniting surface, Non-fire spreading surface

2 / -
Slowly igniting surface, No demands for fire spread

Accommodation:
Walls and ceilings

2 / -
Slowly igniting surface, No demands for fire spread

1 / I
Non igniting surface, Non-fire spreading surface

2 / -
Slowly igniting surface, No demands for fire spread

External surfaces of External wall

1 / I
Non igniting surface, Non-fire spreading surface

1 / I
Non igniting surface, Non-fire spreading surface

2 / -
Slowly igniting surface, No demands for fire spread

Surfaces adjacent to Ventilation gaps

1 / I
Non igniting surface, Non-fire spreading surface

1 / I
Non igniting surface, Non-fire spreading surface

- / -
No requirement



In residential or office buildings of class P1 with not more than 4 storeys, residential or office buildings of class P2 with 3-4 storeys and institutional buildings of class P2, materials of class 2/- may be used for the external surfaces of external walls if:

  • The building is provided with an automatic extinguishing system
  • The spread of fire along the surface of the external wall and the ventilation gaps has been limited by partitioning elements and
  • The hazard of external ignition has been taken into consideration.

 

Tel: (+86) 400-666-7290


 來源:防火網 發布時間:9/20/2011 點擊次數:2610

 上一條: Spain standard UNE 23.727-90 the reaction to fire test

 下一條: EN45545-2 R1材料测试_欧盟车身车体EN 45545-2防火烟毒性测试
 
 
網站首頁 | 測試服務 | 各國標準 | 新聞資訊 | 防火材料 | 會展信息 | 認證服務 | 在線咨詢 | 聯系我們
Copyright © 2009-2023 Firete.com All Right Reserved 蘇公網安備 32010502010088號
服務熱線:+86 25-86583475   備案號:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火網博客