ASTM C1303/C1303M Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation ASTM C1303 闭室泡沫塑料绝缘长期热阻预测用标准试验方法
Rigid gas-filled closed-cell foam insulations include all cellular plastic insulations which rely on a blowing agent (or gas), other than air, for thermal resistance values. At the time of manufacture, the cells of the foam usually contain their highest percentage of blowing agent and the lowest percentage of atmospheric gases. As time passes, the relative concentrations of these gases change due primarily to diffusion. This results in a general reduction of the thermal resistance of the foam due to an increase in the thermal conductivity of the resultant cell gas mixture. These phenomena are typically referred to as foam aging. For some rigid gas-filled closed-cell foam insulation products produced using blowing agent gases that diffuse very rapidly out of the full-thickness foam product, such as expanded polystyrene, there is no need to accelerate the aging process. 5.1.2 Physical gas diffusion phenomena occur in three dimensions. The one-dimensional form of the diffusion equations used in the development of this practice are valid only for planar geometries, that is, for specimens that have parallel faces and where the thickness is much smaller than the width and much smaller than the length. Note 3—Please see Appendix X3 for a discussion of the theory of accelerated aging via thin slicing. Note 4—Theoretical and experimental evaluations of the aging of insulation in radial forms, such as pipe insulation, have been made. (6) However, these practices have not evolved to the point of inclusion in the test standard. The change in thermal resistance due to the phenomena described in 5.1 usually occurs over an extended period of time. Information regarding changes in the thermal resistance of these materials as a function of time is required in a shorter period of time so that decisions regarding formulations, production, and comparisons with other materials can be made. Specifications C578, C591, C1029, C1126 and C1289 on rigid closed-cell foams measure thermal resistance after conditioning at 23 ± 1°C [73 ± 2°F] for 180 ± 5 days from the time of manufacture or at 60 ± 1°C [140 ± 2°F] for 90 days. This conditioning can be used for comparative purposes, but is not sufficient to describe long-term thermal resistance. This requirement demonstrates the importance of the aging phenomena within this class of products. The Prescriptive Method in Part A provides long-term thermal resistance values on a consistent basis for a variety of purposes, including product evaluation, specifications, or product comparisons. The consistent basis for these purposes is provided by a series of specific procedural constraints, which are not required in the Research Method described in Part B. The values produced by the Prescriptive Method correspond to the thermal resistance at an age of five years, which corresponds closely to the average thermal resistance over a 15-year service life (7, 8). It is recommended that any material standard that refers to C1303 to provide a product rating for long-term thermal resistance specify the Part A Test Method of C1303. The Research Method in Part B provides a relationship between thermal conductivity, age, and product thickness. The calculation methods given in Part B can be used to predict the resistance at any specific point in time as well as the average resistance over a specific time period. Note 5—The 5-year aged values produced in Part A can be derived from the Part B data only if all other Part A requirements are met. This test method addresses three separate elements relating to the aging of rigid closed-cell plastic foams. Specimen Preparation—Techniques for the preparation of thin flat specimens, including their extraction from the “as manufactured” product, and the measurement of specimen thickness are discussed. Measurement of the Thermal Resistance—Thermal resistance measurements, taken at scheduled times, are an integral part of the test method. Interpretation of Data—Procedures are included to properly apply the theory and techniques to achieve the desired goals.
1. Scope 1.1 This test method covers a procedure for predicting the long-term thermal resistance (LTTR) of unfaced or permeably faced rigid gas-filled closed-cell foam insulations by reducing the specimen thickness to accelerate aging under controlled laboratory conditions (1-5) . Note 1—See Terminology, 3.2.1, for the meaning of the word aging within this standard. 1.2 Rigid gas-filled closed-cell foam insulation includes all cellular plastic insulations manufactured with the intent to retain a blowing agent other than air. 1.3 This test method is limited to unfaced or permeably faced, homogeneous materials. This method is applied to a wide range of rigid closed-cell foam insulation types, including but not limited to: extruded polystyrene, polyurethane, polyisocyanurate, and phenolic. This test method does not apply to impermeably faced rigid closed-cell foams or to rigid closed-cell bun stock foams. Note 2—See Note 8 for more details regarding the applicability of this test method to rigid closed-cell bun stock foams. 1.4 This test method utilizes referenced standard test procedures for measuring thermal resistance. Periodic measurements are performed on specimens to observe the effects of aging. Specimens of reduced thickness (that is, thin slices) are used to shorten the time required for these observations. The results of these measurements are used to predict the long-term thermal resistance of the material. 1.5 The test method is given in two parts. The Prescriptive Method in Part A provides long-term thermal resistance values on a consistent basis that can be used for a variety of purposes, including product evaluation, specifications, or product comparisons. The Research Method in part B provides a general relationship between thermal conductivity, age, and product thickness. 1.5.1 To use the Prescriptive Method, the date of manufacture must be known, which usually involves the cooperation of the manufacturer. 1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) Other Standards CAN/ULCS770 Standard Test Method for Determination of Long-Term Thermal Resistance of Closed-Cell Thermal Insulation Foams ASTM Standards ASTM C168 Terminology Relating to Thermal Insulation ASTM C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus ASTM C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus ASTM C578 Specification for Rigid, Cellular Polystyrene Thermal Insulation ASTM C591 Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal Insulation ASTM C1029 Specification for Spray-Applied Rigid Cellular Polyurethane Thermal Insulation ASTM C1045 Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions ASTM C1126 Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation ASTM C1289 Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board ASTM D1622 Test Method for Apparent Density of Rigid Cellular Plastics ASTM D6226 Test Method for Open Cell Content of Rigid Cellular Plastics ASTM E122 Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot or Process Index Terms aging; long-term thermal resistance; LTTR; rigid closed-cell plastic foams; scaling factors; thermal insulation; thermal resistance; time-averaged thermal resistance; Aging resistance; Controlled testing conditions/environments; Foamed-in-place thermal insulation; Long-term behavior/performance; Phenolic plastics; Polyisocyanurate insulation; Polystyrene (PS); Polyurethane insulation; Rigid closed cell plastic foams; Rigid thermal insulation; Scaling; Spray-applied thermal insulation; Thermal insulating materials; Thermal resistance/resistivity; Time-averaged thermal resistance; Unfaced thermal insulation;
更多防火阻燃测试认证,请咨询中国防火网 电话:400-666-7290 网址:www.firete.com 邮箱:info@firete.com
... |