ASTM C1289 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board ASTM C1289 贴面硬质泡沫聚乙氰尿酸酯隔热板的标准规范
This specification covers the general requirements for faced thermal insulation boards composed of rigid cellular polyisocyanurate surfaced with other materials. This standard is intended to apply to rigid cellular polyurethane-modified polyisocyanurate thermal insulation board products that are commercially acceptable as nonstructural panels useful in building construction. The materials are classified as follows: Types I, II, III, IV, and V. Under Type I are Classes 1 and 2. Under Type II are Classes 1, 2, and 3. Under Type II Class 1 are Grades 1, 2, and 3. Rigid polyisocyanurate thermal insulation boards shall be based upon the reaction of an isocyanate with a polyol, or the reaction of an isocyanate with itself, or both, using a catalyst and blowing agents to form a rigid closed-cell-structured polyisocyanurate foam. The insulation foam core shall be homogeneous and of uniform density. The following test methods shall be performed to conform to the specified requirements: conditioning; thermal resistance; compressive strength; dimensional stability; flexural strength; tensile strength perpendicular to board surface; water absorption; and water vapor transmission. This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope 1.1 This specification covers the general requirements for faced thermal insulation boards composed of rigid cellular polyisocyanurate surfaced with other materials. The insulation boards are intended for use at temperatures between ?40 and 200°F (?40 and 93°C). This specification does not cover cryogenic applications. Consult the manufacturer for specific recommendations and properties in cryogenic conditions. For specific applications, the actual temperature limits shall be agreed upon by the manufacturer and the purchaser. 1.2 This standard is intended to apply to rigid cellular polyurethane-modified polyisocyanurate thermal insulation board products that are commercially acceptable as non-structural panels useful in building construction. The term polyisocyanurate encompasses the term polyurethane. For engineering and design purposes, users should follow specific product information provided by board manufacturers regarding physical properties, system design considerations and installation recommendations. Note 1—See Appendix X1 for guidance on determining wind pressure resistance of panels when required for wall sheathing applications. 1.3 The use of thermal insulation materials covered by this specification is typically regulated by building codes, or other agencies that address fire performance. Where required, the fire performance of the material shall be addressed through standard fire test methods established by the appropriate governing documents. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 2—For conversion to metric units other than those contained in this standard, refer to . 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) ASTM Standards ASTM C168 Terminology Relating to Thermal Insulation ASTM C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus ASTM C203 Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation ASTM C208 Specification for Cellulosic Fiber Insulating Board ASTM C209 Test Methods for Cellulosic Fiber Insulating Board ASTM C303 Test Method for Dimensions and Density of Preformed Block and Board-Type Thermal Insulation ASTM C390 Practice for Sampling and Acceptance of Thermal Insulation Lots ASTM C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus ASTM C550 Test Method for Measuring Trueness and Squareness of Rigid Block and Board Thermal Insulation ASTM C728 Specification for Perlite Thermal Insulation Board ASTM C1045 Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions ASTM C1058 Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation ASTM C1114 Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus ASTM C1177/C1177M Specification for Glass Mat Gypsum Substrate for Use as Sheathing ASTM C1303 Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation ASTM C1363 Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus ASTM D1621 Test Method for Compressive Properties of Rigid Cellular Plastics ASTM D2126 Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging ASTM E84 Test Method for Surface Burning Characteristics of Building Materials ASTM E96/E96M Test Methods for Water Vapor Transmission of Materials ANSI Standard VoluntaryProductStan Performance Standard for Wood Based structural Use Panels CAN/ULC Standard CAN/ULC-S770-03 Standard Test Method for Determination of Long-Term Thermal Resistance of Closed-Cell Thermal Insulating Foams Index Terms cellular plastic insulation; cellulosic fiber insulating board; composite foam insulation board; faced foam board; foam plastic insulation; oriented strand board; perlite board; polyiso board; polyisocyanurate; polyisocyanurate foam; polyurethane; polyurethane foam; thermal insulation; waferboard: Block and board thermal insulation--specifications; Board thermal insulation--specifications; Cellular thermal insulation--specifications; Cellulose fiber thermal insulation--specifications; Composite foam insulation board; Faced thermal insulation--specifications; Foam plastic insulation; Oriented strand board (OSB); Perlite thermal insulation--specifications; Polyurethane insulation--specifications; Rigid cellular polyisocyanurate; Rigid thermal insulation--specifications; Thermal insulating materials--specifications; Waferboard;
更多防火阻燃测试认证,请咨询中国防火网 电话:400-666-7290 网址:www.firete.com 邮箱:info@firete.com
... |