由于BS476-21耐火测试过程非常复杂,需要在特定的炉具的/特定的测试环境中进行BS476-21耐火测试,因此BS476-21大型耐火测试周期比较长,更多关于BS476-21耐火测试的详细内容,请咨询南京睿督公司,咨询电话:025-8658 3475。
BS476-21: 1987承重材料耐火性测试 BS476-21: Fire test on building materials and structures-Part 21: Method for Determination of the fire resistance of load bearing elements of construction. BS476-21: 建筑材料和构件的防火测试-第21部分: 承重材料耐火性测试
This part, together with BS 476: Parts 20, 22, 23 and supersedes BS 476: Part 8:1972, which is withdrawn. However, the latter will still be made available on request, since it is referred to in the building regulations and other legislative documents.
BS476-21:1987主要用于如下方面: Determination of the fire resistance of beams 横梁的耐火测试 Determination of the fire resistance of columns 圆柱的耐火测试 Determination of the fire resistance of floors and flat roofs 地面材料及天花板的耐火测试 Determination of the fire resistance of walls 墙体的耐火测试
BS 476-21测试方法,样品暴露下高温高压条件下,测试样品在规定时间内(30分钟,60分钟,90分钟,120分钟,150分钟,180分钟)的承重量,完整性、隔热性。
BS476-21测试评估标准: 1.承重量-样品不能支撑测试的承重量被认为测试失败 2.完整性-背火面发生倒塌或者持续的火焰,或者超过给定的抗渗标准。. 3.不渗透性-当火焰出现或者热气引起垫片灼烧,或者形成直径6mm,长度超过150mm的洞,或者直径大于25mm的洞。 4.隔热性-如果出现以下情况被认为失败 a. 背光面温升超过140℃,或者 b. 任何背光面的温升超过180℃。
南京睿督公司全国免费咨询电话:025-8658 3475 400-603-6575 网址:www.fire-test.com 邮箱:info@fire-test.com ... |