1.1 Scope.
1.1.1* This code shall apply to the design, construction, location, installation, operation, and maintenance of refrigerated and nonrefrigerated utility gas plants. Coverage of liquefied petroleum gas systems at utility gas plants shall extend to the point where LP-Gas or a mixture of LP-Gas and air is introduced into the utility distribution system.
 
 
Prevent fires and explosions by following expanded and updated provisions in the 2012 NFPA 59.
NFPA 59 Utility LP-Gas Plant Code applies to the design, construction, location, installation, operation and maintenance of refrigerated and non-refrigerated liquefied petroleum gas utility gas plants. Coverage of liquefied petroleum gas systems at utility gas plants extends to the point where LP-Gas or a mixture of LP-Gas and air is introduced into the utility distribution system.
The 2012 NFPA 59 includes technical changes that impact most users
·    A new section on corrosion protection largely extracts existing requirements from the Code of Federal Regulations, 49 CFR Part 193.
·    A new section addresses training of personnel engaged in maintenance or operation of propane-air mixing equipment.
·    A new section on construction and modification records requires operators to maintain records of the materials of construction for process equipment piping systems containing LPG and other flammable fluids, including their supporting system and foundations for plants that are built or modified after the effective date of the 2012 Edition.
·    Requirements for separation distances for containers less than 2,000 gallons were extracted from NFPA 58 Liquefied Petroleum Gas Code.
·    The provision for vent stacks on nonrefrigerated aboveground containers was removed.
Make the 2012 NFPA 59 part of your tools of the trade.
Work with the most up-to-date safety rules for LP-Gas utility gas plants. Apply the field's latest provisions concerning refrigerated and non-refrigerated containers; piping, valves, and equipment; buildings or structures housing LP-Gas distribution facilities; vaporizers, heat exchangers, and gas-air mixers; relief devices; operations; maintenance; and fire protection, safety, and security. (Softbound, 42 pp., 2012)

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...


 来源:防火网  发布时间:12/9/2013  点击次数:1528

 上一条: NFPA 59A液化天然气生产、储存和处置规范

 下一条: NFPA 550消防安全概念树指南
 
 
网站首页 | 测试服务 | 各国标准 | 新闻资讯 | 防火材料 | 会展信息 | 认证服务 | 在线咨询 | 联系我们
Copyright © 2009-2024 Firete.com All Right Reserved 苏公网安备 32010502010088号
服务热线:025-86583475   备案号:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火网博客