(1). For homogeneous products and substantial components of non-homogeneous products
(2).For any external non-substantial component of non-homogeneous products
(2a) Alternatively, any external non-substantial component having a PCS < 2,0 MJ/m2, provided that the product satisfies the following criteria of EN 13823, FIGRA < 20 W/s, and LFS < edge of specimen, and THR600, < 4,0 MJ, and s1 and d0
(3) For any Internal non-substantial component of non-homogeneous products
(4) For the product as a whole
(5) s1=SMOGRA≤30m2I/s2 and TSP600s≤5OM2 ; s2 =SMOGRA≤180m2I/s2 and TSP600s≤200m2
s3 = not s1 or s2
(6) d0 = No flaming droplets/ particles in EN 13823 within 600s
dl No flaming droplets/ particles persisting longer than 10s in EN 13823 within 600s
d2 = not d0 or d1
Ignition of the paper in EN ISO 11925-2 results in a d2 classification
(7) Pass = no ignition of the paper (no classification);
Fail = ignition of the paper (d2 classification)
(8) Under conditions of surface flame attack and, if appropriate to the end-use application of the product, edge flame attack. |