防火网
本站  
设为首页 加入收藏 网站地图   中文版 繁体 English
 
测试服务: 机车材料防火测试 | 建筑产品防火测试 | 船舶防火测试 | 飞机防火测试 | 耐火测试 | 喷射火测试 | 其他测试
   
用户名:
密码:
验证码:
   
 
主要阻燃防火认证标准
火车船舶汽车建材
 
相关测试方法 更多>>
EN ISO 9239-1:2010地
EN ISO 1182:2010
NF P 92-501
NF P 92-507
法标F级测试
法标I级测试
法国M级测试
EN ISO 1182
EN ISO 9239-1
EN 13501-1
 
首页   美国   ASTM C449矿物纤维水硬化隔热水泥和精细水泥标准规范
 

ASTM C449矿物纤维水硬化隔热水泥和精细水泥标准规范

ASTM C449 Standard Specification for Mineral Fiber Hydraulic-Setting Thermal Insulating and Finishing Cement
ASTM C449 矿物纤维水硬化隔热水泥和精细水泥标准规范

This specification covers mineral fiber (rock or slag) insulating and finishing cement shipped in dry-mix form, including hydraulic-setting binder, which, when mixed with water and applied in accordance with the manufacturer's directions, affords a smooth surface as a final finish for heated surfaces for specific applications. The actual temperature limit shall be agreed upon between the purchaser and the manufacturer. Specimens shall be sampled, prepared, tested, and conform accordingly to the following properties: dry covering capacity, volume change upon drying, compressive strength, linear shrinkage, apparent thermal conductivity, maximum use temperature, and non-combustibility.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

1. Scope
1.1This specification covers mineral fiber (rock or slag) insulating and finishing cement shipped in dry-mix form, including hydraulic-setting binder, which, when mixed with water and applied in accordance with the manufacturer's directions, affords a smooth surface as a final finish for heated surfaces up to 1200°F (649 °C) for specific applications. The actual temperature limit shall be agreed upon between the purchaser and the manufacturer.
Note 1— Precautionary measures should be taken with this material as with other hydraulic-setting mixtures. This material should be used within the time period recommended by the manufacturer.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 The following safety hazards caveat pertains only to the test method (Section 10) described in this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.4 When the installation or use of thermal insulation materials, accessories, and systems pose safety or health problems, the manufacturer shall provide the user with appropriate current information regarding any known problems associated with the recommended use of the company's products and shall also recommend protective measures to be employed in their safe utilization. The user shall establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
ASTM C163 Practice for Mixing Thermal Insulating Cement Samples
ASTM C166 Test Method for Covering Capacity and Volume Change Upon Drying of Thermal Insulating Cement
ASTM C168 Terminology Relating to Thermal Insulation
ASTM C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus
ASTM C356 Test Method for Linear Shrinkage of Preformed High-Temperature Thermal Insulation Subjected to Soaking Heat
ASTM C390 Practice for Sampling and Acceptance of Thermal Insulation Lots
ASTM C411 Test Method for Hot-Surface Performance of High-Temperature Thermal Insulation
ASTM C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
ASTM C795 Specification for Thermal Insulation for Use in Contact with Austenitic Stainless Steel
ASTM C1045 Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions
ASTM C1058 Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation
ASTM C1114 Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus
ASTM E136 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750C
Index Terms
cement; finishing; hydraulic-setting; insulating; mineral fiber; thermal; thermal conductivity;

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...


 来源:防火网 发布时间:12/24/2013 点击次数:1683

 上一条: ASTM C447评估隔热材料的最高使用温度的操作标准

 下一条: ASTM C461与隔热材料一起使用胶合辅料和涂料试验方法
 
 
网站首页 | 测试服务 | 各国标准 | 新闻资讯 | 防火材料 | 会展信息 | 认证服务 | 在线咨询 | 联系我们
Copyright © 2009-2024 Firete.com All Right Reserved 苏公网安备 32010502010088号
服务热线:025-86583475   备案号:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火网博客