ASTM D3353 Standard Test Methods for Fibrous-Insulated Magnet Wire ASTM D3353 纤维绝缘磁性金属丝的标准试验方法
These test methods cover the testing of fibrous-insulated electrical conductors, commonly referred to as magnet wire, which are used in electrical apparatus. The test methods are intended primarily for evaluation of the electrical insulating materials used. It is intended that these test methods be used, except where modified by individual specifications for particular applications. This elongation testing method covers the determination of the elongation of fibrous insulated magnet wire that results in a fracture of the conductor. The electrical resistance testing method covers the determination of the electrical resistance of fibrous insulated magnet wire conductors. The fibrous coverage testing method covers the determination of the quality of fibrous servings on round magnet wire or bare conductor. The measurement of dimensions test methods determine the dimensions of the bare or film insulated conductor and the fibrous-insulated magnet wire. The adhesion and flexibility test method covers the evaluation of the flexibility and adherence of varnished fibrous glass, and varnished or unvarnished fibrous polyester-glass insulating material on either bare conductor, or film-insulated magnet wire. The dielectric breakdown voltage test method covers the determination of the dielectric breakdown voltage in air of insulation on round, rectangular, and square wires at commercial power frequencies. This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope 1.1 These test methods cover the testing of fibrous-insulated electrical conductors, commonly referred to as magnet wire, which are used in electrical apparatus. The test methods are intended primarily for evaluation of the electrical insulating materials used. It is intended that these test methods be used, except where modified by individual specifications for particular applications. 1.1.1 These test methods apply to those magnet wires that are fiber-covered and in which the substrate is bare conductor or is coated with an underlying insulating film as covered by Test Methods D1676. Fiber-covered wires are produced by serving helically or wrapping fibers or fibrous-tape insulation uniformly around the wire in single and multiple layers. The served or wrapped materials are bonded or not bonded to the underlying wire. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
2. Referenced Documents (purchase separately) ASTM Standards ASTM B193 Test Method for Resistivity of Electrical Conductor Materials ASTM D149 Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies ASTM D1676 Test Methods for Film-Insulated Magnet Wire ASTM D1711 Terminology Relating to Electrical Insulation DASTM 5423 Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation ASTM E8 Test Methods for Tension Testing of Metallic Materials Other Standards NEMAStandardsPublica No. MW 1000 on Magnet Wir Index Terms fiber-covered; fibrous coverage; fibrous insulated; fibrous insulation; fibrous tape insulation; glass fiber; magnet wire; polyester-glass fiber; serving; varnish
更多防火阻燃测试认证,请咨询中国防火网 电话:400-666-7290 网址:www.firete.com 邮箱:info@firete.com
... |