1.1 This test method covers the procedure for determining the volume resistivity, measured longitudinally, of extruded crosslinked and thermoplastic semiconducting, conductor and insulation shields for wire and cable. 1.2 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see . 1.3 In common practice the conductor shield is often referred to as the strand shield. 1.4 Technically, this test method is the measurement of a resistance between two electrodes on a single surface and modifying that value using dimensions of the specimen geometry to calculate a resistivity. However, the geometry of the specimen is such as to support the assumption of a current path primarily throughout the volume of the material between the electrodes, thus justifying the use of the term "longitudinal volume resistivity." ( See 3.1.2.1 )
2. Referenced Documents (purchase separately) ASTM Standards ASTM D257 Test Methods for DC Resistance or Conductance of Insulating Materials ASTM D1711 Terminology Relating to Electrical Insulation ASTM D4496 Test Method for D-C Resistance or Conductance of Moderately Conductive Materials Index Terms conductor shield; conductor shielding material; insulation shield; insulation shielding material; moderately conductive; semiconducting shielding materials; semiconducting shields; volume resistivity of shielding materials;
更多防火阻燃测试认证,请咨询中国防火网 电话:400-666-7290 网址:www.firete.com 邮箱:info@firete.com
... |