ASTM D5025 Standard Specification for Laboratory Burner Used for Small-Scale Burning Tests on Plastic Materials ASTM D5025 塑料材料的小型燃烧试验用实验室燃烧器的标准规范
This specification covers the physical dimensions and characteristics of a laboratory burner used for small-scale burning tests on plastic materials, with the supply gases including methane, propane, and butane. The burner shall consist of a burner barrel that threads onto a one-piece base, which is equipped with an orifice and a needle valve that restricts the orifice opening and regulates the gas velocity through the burner, and a gas inlet, which consists of a serrated fitting for connection to the gas supply. A lock nut for securing the barrel onto the base may be provided optionally. The mixing tube of the barrel shall be manufactured with a uniform bore, and the barrel, threads, and serrated fitting shall be free of flash and burrs.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope 1.1 This specification covers the physical dimensions and characteristics of a laboratory burner to be used as an ignition source for small-scale burning tests on plastic materials. The burner is used with methane, propane, or butane supply gases for flame heights of 20 to 125 mm.
Note 1—The burner described in this specification is suitable for use in the following ASTM standards: Specification C 509, Test Method D 229, Test Method D 635, Test Method D 876, Test Method D 3014, Test Method D 3801, Test Method D 4804, Test Method D 4986, and Test Method D 5048. Safety hazards and known limitations on applicability of fire-test-response standards are addressed in the individual test methods.
Note 2—This specification is equivalent to the ignition source specified in IEC 60695-11-3, Annex A and IEC 60695-11-4, Annex A. Note 3—This specification is equivalent to the P/PF2 ignition source specified in ISO 10093.
2. Referenced Documents (purchase separately) ASTM Standards ASTM C509 Specification for Elastomeric Cellular Preformed Gasket and Sealing Material ASTM D229 Test Methods for Rigid Sheet and Plate Materials Used for Electrical Insulation ASTM D635 Test Method for Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position ASTM D876 Test Methods for Nonrigid Vinyl Chloride Polymer Tubing Used for Electrical Insulation ASTM D883 Terminology Relating to Plastics ASTM D1600 Terminology of Abbreviated Terms Relating to Plastics ASTM D3014 Test Method for Flame Height, Time of Burning, and Loss of Mass of Rigid Thermoset Cellular Plastics in a Vertical Position ASTM D3801 Test Method for Measuring the Comparative Extinguishing Characteristics of Solid Plastics in a Vertical Position ASTM D4804 Test Methods for Determining the Flammability Characteristics of Nonrigid Solid Plastics D4986 Test Method for Horizontal Burning Characteristics of Cellular Polymeric Materials D5048 Test Method for Measuring the Comparative Burning Characteristics and Resistance to Burn-Through of Solid Plastics Using a 125-mm Flame ASTM D5207 Practice for Calibration of 20 and 125-mm Test Flames for Small-Scale Burning Tests on Plastic Materials ASTM E176 Terminology of Fire Standards
ISO Standards ISO10093 Plastics--Fire Tests--Standard Ignition Sources
IEC Standards IECTS60695-11-4 Fire Hazard Testing--Part 11-4: Test Flames--500W Flames--Apparatus and Confirmational Test Methods
Index Terms flammability; ignition source; laboratory burner; plastics; small-scale burning tests;