防火网
本站  
设为首页 加入收藏 网站地图   中文版 繁体 English
 
测试服务: 机车材料防火测试 | 建筑产品防火测试 | 船舶防火测试 | 飞机防火测试 | 耐火测试 | 喷射火测试 | 其他测试
   
用户名:
密码:
验证码:
   
 
主要阻燃防火认证标准
火车船舶汽车建材
 
相关测试方法 更多>>
EN ISO 9239-1:2010地
EN ISO 1182:2010
NF P 92-501
NF P 92-507
法标F级测试
法标I级测试
法国M级测试
EN ISO 1182
EN ISO 9239-1
EN 13501-1
 
首页   美国   ASTM D4566远程通信电线和电缆用绝缘体和套管的电气性能特性的标准试验方法
 

ASTM D4566远程通信电线和电缆用绝缘体和套管的电气性能特性的标准试验方法

ASTM D4566 Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable
ASTM D4566远程通信电线和电缆用绝缘体和套管的电气性能特性的标准试验方法

Electrical tests, properly interpreted, provide information with regard to the electrical properties of the insulation. The electrical test values give an indication as to how the insulation will perform under conditions similar to those observed in the tests. Electrical tests may provide data for research and development, engineering design, quality control, and acceptance or rejection under specifications.

1. Scope
1.1 These test methods cover procedures for electrical testing of thermoplastic insulations and jackets used on telecommunications wire and cable and for the testing of electrical characteristics of completed products. To determine the procedure to be used on the particular insulation or jacket compound, or on the end product, reference should be made to the specification for the product.

1.2 The test methods appear in the following sections of this standard:
Test Method Sections
Electrical Tests of Insulation—In-Process 4-8
DC proof test 8
Insulation defect or fault rate 7
Spark test 6
Electrical Tests of Completed Wire and Cable 9-51
Attenuation 24
Attenuation, effects due to aging 31
Attenuation, effects due to elevated temperature 29
Attenuation, effects due to humidity 30
Attenuation to crosstalk ratio—far end (ACR-F) 28
Attenuation to crosstalk ratio—near end (ACR-N) 26
Capacitance deviation 19
Capacitance difference 20
Capacitance unbalance, Pair-to-ground (CUPG) 22
Capacitance unbalance, Pair-to-pair (CUPP) 21
Capacitance unbalance, Pair-to-support wire 23
Characteristic Impedance—Method 1 Propagation constant
and capacitance 47
Characteristic Impedance—Method 2, Single-ended
measurements 48
Characteristic Impedance—Method 3 Least Squares Function Fit 49
Coaxial capacitance (capacitance to water) 17
Conductor continuity 11
Conductor resistance (CR) 13
Conductor resistance unbalance (CRU of pairs) 15
Continuity of other metallic elements 12
Crosses test (continuity between wires of different pairs) 35
Crosstalk loss, far-end 27
Crosstalk loss, near-end 25
DC proof test, Core-to-internal shield (screen) 40
DC proof test, Core-to-shield 38
DC proof test, Core-to-support wire 39
DC proof test, Internal shield (screen)-to-shield 41
DC proof test, Other required isolations 42
DC proof test, Wire-to-wire 37
Fault rate test (air core only) 33
Insulation resistance (IR) 32
Jacket voltage breakdown rating test 36
Mutual capacitance (CM) 18
Mutual conductance 16
Phase Constant 44
Phase Delay 45
Phase Velocity 46
Resistance of other metallic cable elements 14
Shorts test (continuity between wires of a pair) 34
Structural Return Loss and Return Loss 50
Unbalance attenuation (conversion losses) 51
Voltage surge test 43

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Sections 6 and 37.

4.1 In-process electrical tests are used primarily as process control tools in an attempt to minimize the number and magnitude of problems detected at final test of completed cable.

9.1 Electrical tests of completed wire and cable may include verification of some or all of the properties in accordance with Sections 11 through 51.

2. Referenced Documents (purchase separately)
ASTM Standards
ASTM B193 Test Method for Resistivity of Electrical Conductor Materials
ASTM D150 Test Methods for AC Loss Characteristics and Permittivity (Dielectric Constant) of Solid Electrical Insulation
ASTM D1711 Terminology Relating to Electrical Insulation
ASTM D2633 Test Methods for Thermoplastic Insulations and Jackets for Wire and Cable
ASTM D3426 Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials
Using Impulse Waves
ASTM D5423 Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation
ASTM E29 Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications

ANSI Standard
ANSI/IEEEStandard100 IEEE Standard Dictionary of Electrical and Electronics Terms

IEC Standard
IEC61156-1 Multicore and Symmetrical Pair/Quad Cables for Digital Communications--Part 1: Generic Specification

Index Terms
aging; attenuation; attenuation to crosstalk ratio near-end; attenuation to crosstalk ratio far-end; capacitance deviation; capacitance difference; capacitance unbalance pair-to-pair; capacitance unbalance pair-to-ground; capacitance unbalance pair-to-support wire; characteristic impedance; coaxial capacitance; conductor resistance; conductor resistance unbalance; continuity; conversion loss; crosses; crosstalk loss—far end; crosstalk loss—near end; dc proof test; equal level far-end crosstalk; equal level unbalance attenuation far-end; equal level unbalance attenuation near-end; equal level longitudinal conversion transfer loss (EL LCTL); equal level transverse conversion transfer loss (EL TCTL); fault rate test; humidity; insulation defect; insulation resistance; jacket voltage breakdown; longitudinal conversion loss (LCL); longitudinal conversion transfer loss (LCTL); mutual capacitance; mutual conductance; phase constant; phase delay; phase velocity; shorts test; spark test; structural return loss; transverse conversion loss (TCL); transverse conversion transfer loss (TCTL); unbalance attenuation far-end; unbalance attenuation near-end; voltage surge test; Aging; Attenuation; Capacitance difference/deviation/unbalance; Characteristic impedance; Coaxial capacitance; Communications; Conductor continuity/resistance; Cross section data/analysis--insulation; D-C voltage test; Defects; Spark testing; Structural return loss; Telecommunications; Thickness--electrical insulating materials; Voltage surge test; Electrical performance; Fault rate; Impedance; Jacket voltage breakdown; Insulated wire and cable; Insulation adhesion//compression//shrinkback; Insulation defects; LCL/LCTL (longitudinal conversion/transfer loss); Insulation resistance; Jacket bonding//notch//peel//shrinkback//slip strength; Melt flow; Mutual conductance/capacitance; Oil immersion; Performance--electrical insulation; Phase delay/constant/velocity; Shorts test;

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...


 来源:防火网 发布时间:11/4/2013 点击次数:2673

 上一条: ASTM D4565远程通信电线和电缆用绝缘体和套管物理和环境性能特性标准试验方法

 下一条: ASTM D4652电绝缘用硅酮液的标准规范
 
 
网站首页 | 测试服务 | 各国标准 | 新闻资讯 | 防火材料 | 会展信息 | 认证服务 | 在线咨询 | 联系我们
Copyright © 2009-2024 Firete.com All Right Reserved 苏公网安备 32010502010088号
服务热线:025-86583475   备案号:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火网博客