Flammability testing in accordance with DIN 51960. As a result the size of the burned spot is examined and the fact whether the fire is self-extinguishing. If the size burned spot is within 50mm, the classification is class 1, if the burnt area is bigger, the sample is classified as class 2. The flammability test is carried out five times.
Sample requirement
The burning behaviour test is carried out on a 1*1m2 sample.
|