防火网
本站  
设为首页 加入收藏 网站地图   中文版 繁体 English
 
测试服务: 机车材料防火测试 | 建筑产品防火测试 | 船舶防火测试 | 飞机防火测试 | 耐火测试 | 喷射火测试 | 其他测试
   
用户名:
密码:
验证码:
   
 
主要阻燃防火认证标准
火车船舶汽车建材
 
相关测试方法 更多>>
EN ISO 9239-1:2010地
EN ISO 1182:2010
NF P 92-501
NF P 92-507
法标F级测试
法标I级测试
法国M级测试
EN ISO 1182
EN ISO 9239-1
EN 13501-1
 
首页   欧盟   封堵材料EN1366-3耐火测试及CE Marking
 

封堵材料EN1366-3耐火测试及CE Marking

防火封堵材料Firestop material需要符合英国及欧盟标准BS EN 1366-3的耐火测试要求,南京睿督公司提供英国UKAS资质Warringtonfire实验室所出具的Collar及Wrap型号的EN1366-3耐火测试报告,(90min,120min,150min,240min)以及封堵材料CE Marking(欧盟CE认证),咨询电话:025-8658 3475,网址:www.fire-test.com  

EN 1366-3耐火测试标准名称
EN 1366-3: Fire resistance tests for service installations- Part 3: Penetration seals.
EN 1366-3: 服务设施耐火测试-第3部分:穿透性密封件
 
EN 1366-3耐火测试方法
样品暴露在高温高压条件下,测试样品在规定时间内(30分钟、60分钟、90分钟、120分钟等)的承重量,完整性、隔热性。
 
EN 1366-3耐火测试性能评定
失去完整性:当棉垫被点燃或者背火面燃烧达10秒钟以上时,被认为试件失去完整性;测试过程中,6mm直径的探棒可穿过裂缝进入炉内且探棒可沿裂缝长度方向不小于150mm; 直径25mm的探棒可穿过裂缝进入炉内时,则被认为试件失去完整性。
 
失去隔热性: 试件背火面的平均温升超过试件表面初始平均温度140℃或者背火面在任何一点的温升超过该点初始温度180℃时,则被认为试件失去隔热性。

失去承重性:在试验过程中试件发生垮塌;或梁板构件的最大挠度、柱构件的轴向变形、柱构件的轴向变形速率超过规定值时,则被认为试件失去承重性。
 
EN 1366-3服务设施耐火测试-标准名称:
 
EN 1366-1: Fire resistance tests for service installations- Part 1: Ducts
EN 1366-2: Fire resistance tests for service installations- Part 2: Fire dampers

EN 1366-3: Fire resistance tests for service installations- Part 3: Penetration seals.
EN 1366-3: 服务设施耐火测试-第3部分:穿透性密封件
 
EN 1366-4: Fire resistance tests for service installations- Part 4: Linear joint seals.
EN 1366-4: 服务设施耐燃测试-第4部分:线性密封件
 
EN 1366-5: Fire resistance tests for service installations- Part 5: Service ducts and shafts.
EN 1366-5: 服务设施耐燃测试 - 第5部分:服务管道和竖井
 
EN 1366-6: Fire resistance tests for service installations- Part 6: Raised access and hollow core floors.
EN 1366-6: 服务设施耐燃测试 - 第6部分:高架地板和中空地板
 
EN 1366-7: Fire resistance tests for service installations- Part 7: Conveyor systems and trackbound transportation systems (in course of preparation)
EN 1366-8: Fire resistance tests for service installations- Part 8: Smoke extraction ducts
EN 1366-9: Fire resistance tests for service installations- Part 9: Single compartment smoke extraction ducts (in course of preparation).
EN 1366-10: Fire resistance tests for service installations- Part 9: Smoke control dampers  (in course of preparation)

CE Marking for Fire Collars, Wraps and Sleeves
Why our Fire Collars, Wraps and Sleeves are CE Marked?
Under The Construction Products Regulation (CPR) In July 2013 it became a legal requirement for many life safety products to be CE Marked.

To comply, products must be fixed with a CE Mark after undergoing extensive independent third party testing. Quelfire QWR Fire Collars, QWW Intuwraps and QRS Fire Sleeves have been fire tested to BS EN 1366-3: 2009 at Exova Warringtonfire and under gone durability testing. In addition continuous factory production controls and external auditing by Warrington Certification are undertaken.

This law applies to any construction product covered by a harmonised European standard (hEN). Any product which falls under a hEN but is not CE Marked can no longer be supplied or installed in the UK or the rest of Europe.

更多关于封堵材料EN1366-3耐火测试及CE Marking,请咨询南京睿督公司
南京睿督公司咨询电话:400-603-6575  025-8658 3475
网址:
www.fire-test.com    www.fire-test.cn  
邮箱:info@fire-test.com
 
……


 来源:防火网 发布时间:12/31/2020 点击次数:1178

 上一条: 青岛地铁1号线采用的非金属材料均满足国际最高防火标准BS6853及EN45545

 下一条: ECE R118防火测试主要关注哪些测试项目?
 
 
网站首页 | 测试服务 | 各国标准 | 新闻资讯 | 防火材料 | 会展信息 | 认证服务 | 在线咨询 | 联系我们
Copyright © 2009-2024 Firete.com All Right Reserved 苏公网安备 32010502010088号
服务热线:025-86583475   备案号:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火网博客