首页   美国   ASTM D149脲甲醛树脂溶液中不挥发物含量的标准测试方法
 

ASTM D149脲甲醛树脂溶液中不挥发物含量的标准测试方法

ASTM D149 Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies
ASTM D149 脲甲醛树脂溶液中不挥发物含量的标准测试方法

The dielectric strength of an electrical insulating material is a property of interest for any application where an electrical field will be present. In many cases the dielectric strength of a material will be the determining factor in the design of the apparatus in which it is to be used.
Tests made as specified herein are suitable for use to provide part of the information needed for determining suitability of a material for a given application; and also, for detecting changes or deviations from normal characteristics resulting from processing variables, aging conditions, or other manufacturing or environmental situations. This test method is useful for process control, acceptance or research testing.
Results obtained by this test method can seldom be used directly to determine the dielectric behavior of a material in an actual application. In most cases it is necessary that these results be evaluated by comparison with results obtained from other functional tests or from tests on other materials, or both, in order to estimate their significance for a particular material.
Three methods for voltage application are specified in Section 12: Method A, Short-Time Test; Method B, Step-by-Step Test; and Method C, Slow Rate-of-Rise Test. Method A is the most commonly-used test for quality-control tests. However, the longer-time tests, Methods B and C, which usually will give lower test results, will potentially give more meaningful results when different materials are being compared with each other. If a test set with motor-driven voltage control is available, the slow rate-of-rise test is simpler and preferable to the step-by-step test. The results obtained from Methods B and C are comparable to each other.
Documents specifying the use of this test method shall also specify:
Method of voltage application,
Voltage rate-of-rise, if slow rate-of-rise method is specified,
Specimen selection, preparation, and conditioning,
Surrounding medium and temperature during test,
Electrodes,
Wherever possible, the failure criterion of the current-sensing element, and
Any desired deviations from the recommended procedures as given.
If any of the requirements listed in 5.5 are missing from the specifying document, then the recommendations for the several variables shall be followed.
Unless the items listed in 5.5 are specified, tests made with such inadequate reference to this test method are not in conformance with this test method. If the items listed in 5.5 are not closely controlled during the test, it is possible that the precisions stated in 15.2 and 15.3 will not be obtained.
Variations in the failure criteria (current setting and response time) of the current sensing element significantly affect the test results.
Appendix X1. contains a more complete discussion of the significance of dielectric strength tests.
1. Scope
1.1 This test method covers procedures for the determination of dielectric strength of solid insulating materials at commercial power frequencies, under specified conditions. ,
1.2 Unless otherwise specified, the tests shall be made at 60 Hz. However, this test method is suitable for use at any frequency from 25 to 800 Hz. At frequencies above 800 Hz, dielectric heating is a potential problem.
1.3 This test method is intended to be used in conjunction with any ASTM standard or other document that refers to this test method. References to this document need to specify the particular options to be used (see 5.5).
1.4 It is suitable for use at various temperatures, and in any suitable gaseous or liquid surrounding medium.
1.5 This test method is not intended for measuring the dielectric strength of materials that are fluid under the conditions of test.
1.6 This test method is not intended for use in determining intrinsic dielectric strength, direct-voltage dielectric strength, or thermal failure under electrical stress (see Test Method D3151).
1.7 This test method is most commonly used to determine the dielectric breakdown voltage through the thickness of a test specimen (puncture). It is also suitable for use to determine dielectric breakdown voltage along the interface between a solid specimen and a gaseous or liquid surrounding medium (flashover). With the addition of instructions modifying Section 12, this test method is also suitable for use for proof testing.
1.8 This test method is similar to IEC Publication 243-1. All procedures in this method are included in IEC 243-1. Differences between this method and IEC 243-1 are largely editorial.
1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7. Also see 6.4.1.
 
2. Referenced Documents (purchase separately)
ASTM Standards
ASTMD374 Test Methods for Thickness of Solid Electrical Insulation
ASTMD618 Practice for Conditioning Plastics for Testing
ASTMD877 Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes
ASTMD1711 Terminology Relating to Electrical Insulation
ASTMD2413 Practice for Preparation of Insulating Paper and Board Impregnated with a Liquid Dielectric
ASTMD3151 Test Method for Thermal Failure of Solid Electrical Insulating Materials Under Electric Stress
ASTMD3487 Specification for Mineral Insulating Oil Used in Electrical Apparatus
ASTMD5423 Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation
IEC Standard
Pub.243-1 Methods of Test for Electrical Strength of Solid Insulating Materials--Part 1: Tests at Power Frequencies
ANSI Standard
C68.1 Techniques for Dielectric Tests, IEEE Standard No.
Index Terms
breakdown; breakdown voltage; calibration; criteria of breakdown; dielectric breakdown voltage; dielectric failure; dielectric strength; electrodes; flashover; power frequency; process-control testing; proof testing; quality-control testing; rapid rise; research testing; sampling; slow rate-of-rise; step-by-step; surrounding medium; voltage withstand; Commercial power frequencies; Dielectric breakdown voltage; Electrical properties; Power factor

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...
 


 来源:防火网  发布时间:12/10/2013  点击次数:1710

 上一条: NFPA 650气压输送系统处理可燃固体颗粒标准

 下一条: ASTM D1428钠和钾在水与水环境的火焰光谱法试验方法标准
 
 
网站首页 | 测试服务 | 各国标准 | 新闻资讯 | 防火材料 | 会展信息 | 认证服务 | 在线咨询 | 联系我们
Copyright © 2009-2024 Firete.com All Right Reserved 苏公网安备 32010502010088号
服务热线:025-86583475   备案号:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火网博客