Home station  
Set as homepage Add to favorites    中文版 繁体 English
 
Testing to: Rolling Fire testing | Building Fire testing | Marine material | Aircraft material | Fire Resistance | Jet Fire | Other
Company logo
Contact Information
Contact:Ms Li
Department:
Post:
Tel:025-86583035
Mobile:
Fax:
Email: info@firete.com
Add: No.118 Middle JiangdongRoad,Nanjing,Jiangsu,210012,China
Website: http://www.firete.com
Enterprise basic information
Type:
Business:
Number of employees:保密
 
Home About Products Business
 Location:Home > Firete.com > EN 13501-1/EN 9239-1/EN 13823/EN 11925-2/EN 1716
EN 13501-1/EN 9239-1/EN 13823/EN 11925-2/EN 1716
Release Date:2/24/2011  Hits:3886

EN 13501-1:2007A1+2010 Classification using data from reaction to fire tests

1. Standard - EN 13501-1:2007A1+2010
 EN 13501-1:2007A1+2010 Fire classification of construction products and building elements-Part 1: Classification using data from reaction to fire tests.

EN 13501-1 according to requirements and test results, divided into seven levels: A1, A2, B, C, D, E, F
EN13501-1 related standard:
EN ISO 1182: non –combustibility test
EN ISO 1716: heat of combustion test
EN 13823: single burning item test
EN ISO 9239-1: determination of the burning behaviour of floorings, using a radiant heat source
EN ISO 11925-2: ignitability test

2. Standard Brief-- EN 13501-1:2007A1+2010
Flammability classification:A1、A2、B、C、D、E、F or AFL1、AFL2、BFL、CFL、DFL 、EFL 、FFL or AL1、AL2、BL、CL、DL 、EL 、FL
Toxicity:T0、T1、T2
Smoke density:S1、S2、S3
dripping:D0、D1、D2

3. Test method and classification
3.1 Classes of reaction to fire performance for construction products excluding floorings
Class A1: According to EN ISO 1182 and ISO EN 1716; meet to the standards.
Class A2: According to EN ISO 1182、EN ISO 1716 and EN ISO 13823; meet to the standards.
Class B、C、D: According to ISO EN 13823、EN ISO 11925-2; meet to the standards.
Class E: According to EN ISO 11925-2; meet to the standards.
Class F: According to EN ISO 11925-2; fail to the standards.

3.2 Classes of reaction to fire performance for floorings
Class AFL1: According to EN ISO 1182 and ISO EN 1716; meet to the standards.
Class AFL2: According to EN ISO 1182、EN ISO 1716 and EN ISO 9239-1; meet to the standards.
Class BFL、CFL、DFL: According to EN ISO 9239-1、EN ISO 11925-2; meet to the standards.
Class EFL: According to EN ISO 11925-2; meet to the standards.
Class FFL: According to EN ISO 11925-2; meet to the standards.

3.3 Classes of reaction to fire performance for linear pipe thermal insulation products.
Class AL1: According to EN ISO 1182 and ISO EN 1716; meet to the standards.
Class AL2: According to EN ISO 1182、EN ISO 1716 and EN ISO 13823; meet to the standards.
Class BL、CL、DL: According to ISO EN 13823、EN ISO 11925-2; meet to the standards.
Class EL: According to EN ISO 11925-2; meet to the standards.
Class FL: According to EN ISO 11925-2; fail to the standards.


EN 13501-1 is similar with GB 8624:2006