Fire resisting、Non propagation of fire、Flame retardant test、Smoke density、Toxicity、
Corrosivity、HCI emission、
BS 4066-1(EN 50265): Method of test on a single vertical insulated wire or cable.
BS 4066-3 EN 50266): Method for classification of flame propagation
characteristics of bunched cables.
BS 6387: Specification for performance requirements for cables requirement to maintain circuit integrity
under fire conditions.
BS 6245-1 (EN 50267-2-1): Method of determination of amount of halogen acid gas evolved during combustion
of polymeric materials taken from cables.
BS 6425-2 (EN 50267-2-2): Determination of degree of acidity (corrosivity) of gases by measuring PH and
conductivity.
BS 6724, Appendix F: Measurement of smoke density using the 3m test cube (Absorbance).
BS 7622 (EN 50268): Measurement of smoke density of electric cables burning under defined conditions
(LT).
CEI 20-17: Fire retardant rubber insulated cables with low emission of smokes and toxic and corrosive
gases for train, trams and alike.
CEI 20-22-2 (EN 50266): Tests on bunched wires or cables
CEI 20-35-1(EN 50265): Test on a single vertical insulated wire or cable.
CEI 20-36: Fire-resisting characteristics of electric cables.
CEI 20-37-2-1(EN 50267-2-1): Method for determination of amount of halogen acid gas evolved during
combustion of polymeric materials taken from cables.
CEI 20-37-2-2(EN 50267-2-12): Determination of degree of acidity (corrosivity) of gases by measuring PH
and conductivity.
CEI 20-37-3 (EN 50268-1): Measurement of smoke density of electric cables burning under defined
conditions (LT).
CEI 20-38: Fire retardant rubber insulated cables with low emission of smoke and toxic and corrosive
gases.
DEF STD 61-12-18: Equipment wires limited fire hazard.
DIN 4102-12: Circuit integrity maintenance of electric cable systems-Requirements and testing.
EN 50200:2000-02—Methods of test for resistance to fire of unprotected smell cables for use in emergency
circuit.
IEC 60331: Fire-resisting characteristics of electric cables.
IEC 60332-1: Test on a single vertical insulated wire or cable
IEC 60332-2: Test on a single small vertical insulated copper wire or cable
IEC 60332-3: Test on bunched wires or cables.
IEC 60754-1: Method for determination of amount of halogen acid gas evolved during combustion of
polymeric materials taken from cables.
IEC 60754-2: Measurement of smoke density of electric cables burning under defined conditions (LT).
IEC 61034-2: Measurement of smoke density of electric cables burning under defined condition (LT).
IEEE 383, Section 2.5.1: Flame test on grouped cables in vertical tray.
NES 713: Determination of the toxicity index of the products of combustion from small specimens of
material.
NF X 70-100: Fire behaviour tests-Analysis of pyrolysis and combustion gased-Pipe still method.
NF C 32-070: Insulated conductors and cables for installation
classification tests on conductors and cables with regard to fire behaviour.
Singapore Std 299-1: Performance requirement for cables required to maintain circuit integrity under fire
conditions.
UIC 895: Technical specification for the supply of insulated electric cables for railway vehicles.
UITP-APTA: Electric wires and cables used in underground transit systems.
UTE C 20-454: Test method, fire behaviour, determination of gases analysis.
VDE 0472-814: Testing of cables and flexible cords fire resisting characteristics of electric cables.
中国防火网专业提供BS6853测试、NFF16-101测试、DIN5510-2测试、NFPA130测试
全国免费咨询电话: 400-666-7290