DIN5510 European Fire Safety Certificate for train industry DIN5510-2 test

DIN5510-2:2009-05: preventive fire protect in railway vehicle parts 2: Fire behaviour and fireside effects of material and parts FireTe worked with Nanjing Smart products service company (0086-25-8658 3475) concerning for the European train industry such as German DIN5510, British BS6853, French NFF16-101 test and certification.
DIN5510-2:2009-05:铁路车辆防止燃烧-第二部分:材料和构件的燃烧特性和燃烧并发现,FireTe中国防火网同南京睿督产品服务有限公司(025-86583475)一并关注于欧洲的火车防火阻燃和烟雾毒性方面的测试事宜,主要的标准为德国的DIN5510,英国的BS6853和法国的NFF16-101的测试和认证。

1. DIN5510-2 standard
DIN 5510-2:2009-05 Preventive fire protect in railway vehicle, part 2: Classification, requirement and test method.
 
General materials for DIN5510-2 test contain four different tests: Burning test, smoke development test, droplet test and Toxicity test。
 
2. DIN 5510-2 Burning testing
 
Test method: DIN 54837:2007
 
DIN 54837:2007 standard for Burning test、smoke development test and droplet test.
 
2.1Burning test: S2-S5(S2、S3、S4、S5),The classification according to damage range and after the burning time.
                                                                              S2- S5 Burning testing

classification
S2
S3
S4
S5
damage range
≤30cm
≤25cm
≤20cm
0cm
after the burning time
No requirement
≤100s
≤10s
0s

 
2.2 Smoke development classification: not meet the SR1,SR1-SR2
 
                                                                 Smoke development classification

classification
requirement
Not meet the SR1
>100(%*min)
SR1
≤100(%*min)
SR2
≤50(%*min)

 
2.3 Droplet testing: ST1-ST2
                                                                            Droplet testing

classification
requirement
ST1
Droplet
ST2
No Droplet

 
2.4 Sample: 8ps*500mm*190mm* thickness (thickness less than 25mm)
 
 
3.1 DIN5510-2 Toxicity requirement : FED (tzul)≤1
 
3.2 Test method: DIN EN ISO 5659-2
 
In a test chamber specified by DIN EN ISO 5659-2, the specimens are exposed to radiant heat of 25 kw/m2 . The concentration of following gases were measured: CO2、CO、HF、HCI、HCN、NO2、SO2、HBr.
 