Floor covering for DIN5510-2 test contain two tests: flammability test and toxicity test, Please Contect 400-666-7290.
DIN 5510-2:2009-05 Preventive fire protect in railway vehicle, part 2: Classification, requirement and test method.
Floor covering for DIN 5510-2 flammability test
Flammability classification: SF1-SF3(SF1、SF2、SF3)
The flammability classifications according to Critical heat flux (CHF) and smoke obscuration.
SF1 (Critical heat flux (CHF)≥2.5KW/m2,smoke obscuration:Not requirement);SF2(Critical heat flux (CHF)≥2.5KW/m2,smoke obscuration ≤2500(%*min));SF3(Critical heat flux (CHF)≥4.5KW/m2,smoke obscuration≤750(%*min))
DIN5510-2 Toxicity requirement : FED (tzul)≤1,Test method: DIN EN ISO 5659-2, In a test chamber specified by DIN EN ISO 5659-2, the specimens are exposed to radiant heat of 25 kw/m2. The concentration of following gases were measured: CO2、CO、HF、HCI、HCN、NO2、SO2、HBr.