DIN 54837:2007 Testing of materials, small components and component sections for rail vehicles-Determination of burning behaviour using a gas burner.
DIN54837 the test method is used to DIN 5510-2 in the S2-S5 burning level test.
S2: damage range ≤ 30cm
S3: damage range ≤ 25cm, after the burning time ≤ 100S
S4: damage range ≤ 20cm, after the burning time ≤ 10S
S5: damage range = 0cm, after the burning time = 0S
S2: damage range ≤ 30cm
S3: damage range ≤ 25cm, after the burning time ≤ 100S
S4: damage range ≤ 20cm, after the burning time ≤ 10S
S5: damage range = 0cm, after the burning time = 0S
DIN 54837 the test can also smoke development (does not meet the SR1, SR1-SR2) and droplet test (ST1-ST2)
classification | S2 | S3 | S4 | S5 |
damage range | ≤30cm | ≤25cm | ≤20cm | 0cm |
after the burning time | No requirement | ≤100s | ≤10s | 0s |
Smoke development classification
classification | requirement |
Not meet the SR1 | >100(%*min) |
SR1 | ≤100(%*min) |
SR2 | ≤50(%*min) |
Droplet testing
classification | requirement |
ST1 | Droplet |
ST2 | No Droplet |