防火阻燃测试--中国防火网 400-603-6575

中国防火网专注于英国防火测试BS6853,法国防火测试NFF16-101,德国防火测试DIN5510-2,美国防火测试NFPA130,欧标EN45545等防火阻燃测试

« ASTM C578硬质多孔聚苯乙烯热绝缘材料标准规范EN13501-1:2007+A1:2009欧盟防火标准A2级防火要求 »

ASTM C591-2012非表面加工的硬质蜂窝状聚氨基甲酸乙酯绝热材料的标准规范

1. ASTM C591标准适用范围

1.1 This specification covers the types, physical properties, and dimensions of unfaced, preformed rigid cellular polyisocyanurate plastic material intended for use as thermal insulation on surfaces from -297°F (-183°C) to 300°F (149°C). For specific applications, the actual temperature limits shall be agreed upon by the manufacturer and purchaser.

1.2 This specification only covers “polyurethane modified polyisocyanurate” thermal insulation which is commonly referred to as “polyisocyanurate” thermal insulation. This standard does not encompass all polyurethane modified materials. Polyurethane modified polyisocyanurate and other polyurethane materials are similar, but the materials will perform differently under some service conditions.

1.3 This standard is designed as a material specification, not a design document. Physical property requirements vary by application and temperature. At temperatures below -70°F (-51°C) the physical properties of the polyisocyanurate insulation at the service temperature are of particular importance. Below -70°F (-51°C) the manufacturer and the purchaser must agree on what additional cold temperature performance properties are required to determine if the material can function adequately for the particular application.

1.4 This standard addresses requirements of unfaced preformed rigid cellular polyisocyanurate thermal insulation manufactured using blowing agents with an ozone depletion potential of 0 (ODP 0).

1.5 When adopted by an authority having jurisdiction, codes that address fire properties in many applications regulate the use of the thermal insulation materials covered by this specification. Fire properties are controlled by job, project, or other specifications where codes or government regulations do not apply.

1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. ASTM C591参考标准

ASTM C168 Terminology Relating to Thermal Insulation
ASTM C303 Test Method for Dimensions and Density of Preformed Block and Board-Type Thermal Insulation
ASTM C335 Test Method for Steady-State Heat Transfer Properties of Pipe Insulation
ASTM C390 Practice for Sampling and Acceptance of Thermal Insulation Lots
ASTM C871 Test Methods for Chemical Analysis of Thermal Insulation Materials for Leachable Chloride, Fluoride, Silicate, and Sodium Ions
ASTM C1363 Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus
ASTM D1622 Test Method for Apparent Density of Rigid Cellular Plastics
ASTM D6226 Test Method for Open Cell Content of Rigid Cellular Plastics
ASTM E96/E96M Test Methods for Water Vapor Transmission of Materials