防火阻燃测试--中国防火网 400-603-6575

中国防火网专注于英国防火测试BS6853,法国防火测试NFF16-101,德国防火测试DIN5510-2,美国防火测试NFPA130,欧标EN45545等防火阻燃测试

« BS6853 Annex D8.5 smoke density test using seat test methodBS6853 Annex D8.7 smoke density test using cable test method »

BS6853 Annex D8.6 smoke density test using floor test method

1. Standard- BS6853 Annex D8.6
BS6853 Annex D: Methods for measuring smoke density
BS6853:1999 Code of practice for fire precautions in the design and construction of passenger carrying trains.

BS 6853 Annex D.8.6 is utilized for interior and exterior horizontal supine surfaces (Tables 1 and 4 of BS 6853:1999) and mattresses (table 12 of BS 6853: 1999).

2. Standard Brief-BS6853 Annex D8.6
The smoke density measurement taken from a material under fire conditions gives an indication of the visibility through the smoke, this is important as reduced visibility in a real fire situation makes it more difficult to escape from a fire hence increasing the threat to human life from the toxic gases, flames and heat.

BS6853 Annex D.8.6—smoke density test using floor test method

3. BS6853:1999 Standard requirement for Smoke density testing
Interior horizontal supine surface for BS6853 (BS6853 table 1) requirement: A0≤220
Exterior horizontal supine surface for BS6853 (BS6853 table 4) requirement: A0≤370
Mattresses for BS6853 (BS6853 table 12) requirement: A0≤220

Tel : (+0086) 25 8658 3475    (+0086) 400-666-7290
E-mail: info@firete.com
Website: www.firete.com   www.fire-test.com
 

发表评论:

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。

日历

最新评论及回复

最近发表

Powered By DIN5510-2 DIN5510

中国防火网 版权所有