EN ISO 1716 Determination of the heat of combustion

EN ISO 1716:2002 Reaction to fire tests for building Products- Determination of the heat of combustion

 EN ISO 1716 The standard similar with GB/T 14402-2007
...

EN 13501-1:2007A1+2009 Classification using data from reaction to fire tests

 

 EN 13501-1:2007A1+2009 Fire classification of construction products and building elements-Part 1: Classification using data from reaction to fire tests.
...

DIN EN 50305:2002. Railway rolling cables having special fire performance. Test method.

 

DIN EN 50305:2002. Railway application-Railway rolling cables having special fire performance. Test method.
 
Flame propagation
...

EN 50264-1: Railway rolling stock power and control cables having special fire performance

 

 
EN 50264-1 Railway applications-Railway rolling stock power and control cables having special fire performance-Part 1: General requirements.
 
Flame propagation (flame spread)-bunched cables
...

DIN EN 60695-11-10: 50W horizontal and vertical flame test methods

DIN EN 60695-11-10: Fire hazard testing-Part11-10: Test flames – 50W horizontal and vertical flame test methods.

 This part of EN 60695 specifies a small-scale laboratory screening procedure for comparing the relative burning behaviour of vertically or horizontally oriented specimens made from plastic and other non-metallic materials, exposed to a small-flame ignition source of 50W nominal power.
...

DIN EN 60332-1-2:2004 vertical flame propagation for a single insulated wire or cable

DIN EN 60332-1-2:2004 Tests on electric and optical fibre cables under fire conditions—Part 1-2: Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 KW pre-mixed flame and is for general use, except that the procedure specified of less than 0.5mm2 total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completes. In these cases, the procedure giver in DIN EN IEC 60332-2-2 is recommended.

...

DIN EN 50266-2-4 vertical flame spread of vertically-mounted bunched wires or cables

 

EN 50266-2-4:2001: Common test methods for cable under fire condition—Test for vertical flame spread of vertically-mounted bunched wires or cables –Part 2-5: Procedures –Category C
...

DIN 54837:2007 Determination of burning behaviour using a gas burner

DIN 54837:2007 Testing of materials, small components and component sections for rail vehicles-Determination of burning behaviour using a gas burner.

 
DIN54837 the test method is used to DIN 5510-2 in the S2-S5 burning level test.
...

DIN 4102-14:1990 floor covering systems using a radiant heat source

 

1.Standard-- DIN 4102-14
DIN 4102-14:1990 Fire behaviour of building materials and elements; determination of the burning behaviour of floor covering systems using a radiant heat source.
...

BS 6853 Annex D: smoke density

 

BS 6853 Annex D/smoke density/BS 6853
 
BS 6853 Annex D: Methods for measuring smoke density
 
The smoke density measurement taken from a material under fire conditions gives an indication of the visibility through the smoke, this is important as reduced visibility in a real fire situation makes it more difficult to escape from a fire hence increasing the threat to human life from the toxic gases, flames and heat.
...
分页:[«][300]301[302][303][304][305][306][307][308][309][310][311][312][313][314][»]

日历

<< 2021-12 >>

Sun

Mon

Tue

Wed

Thu

Fri

Sat

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

Powered By DIN5510-2 DIN5510

中国防火网 版权所有